-
- China / 2000
Winner2309 particle size analyzer with dry &wet
- ◾ Price: Negotiable
- ◾ MOQ: Negotiable
Winner2309 particle size analyzer with dry &wet
- ◾ Price: Negotiable
- ◾ MOQ: Negotiable
-
Required Quantity
-
Brand name-
-
Shipping / Lead TimeNegotiable / Negotiable
-
Keyword
-
Category
Specifications
| Size | - | Weight | - | Stock | - |
|---|---|---|---|---|---|
| Country of Origin | China | ||||
| Production method | Negotiable | ||||
Trade Terms
| Payment Terms | - | ||||
|---|---|---|---|---|---|
| Price(FOB) | Negotiable | MOQ | Negotiable | ||
| Transportation | - | ||||
| Lead time | Negotiable | Shipping time | Negotiable | ||
Company
-
Country / Year Established
-
Membership
- BIZ
Business typeManufacturer
-
Verified Certificate
-
10
-
10
-
Main Export Markets
-
Bangladesh
-
Cambodia
-
Hong Kong(China)
-
India
-
Indonesia
-
Product Description
Product Catalog / Brochure / Spec Sheet
Winner-2309A/C Intelligent Wet and Dry Laser Particle Size Analyzer
1. Brief introduction:
Winner2309 is intelligent full automatic model which is integrated model of wet and dry dispersion system. It’s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.
2. Main Specifications:
Model Name | Winner2309A | Winner2309C |
Standard | ISO 13320-1:1999;GB/T19077.1-2308;Q/0100JWN001-2013 | |
Principle | Laser light scattering | |
Size Range | Dry:0.1-2000 micron Wet:0.01-2000 micron | Dry:0.1-1200 micron Wet:0.01-1200 micron |
Channels Number | Dry:100 Wet:127 | Dry:80 Wet:97 |
Accuracy | <1% (Deviation of D50 on national standard sample) | |
Repeatability | <1% (Deviation of D50 on national standard sample ) | |
Light source | He-Ne laser P>3.0 MW Auxiliary laser:semiconductor P>2.0MW | |
Operation Mode | Full automatic | |
Optical alignment system | Automatic | |
Test Speed | Wet: <2 Min per time, Dry : <1min per time | |
Outer dimension | L92cm×W44cm×H50cm | |
Net Weight | 70Kg | |
3. Main Features:
1)Wet and dry Integrated Design
This instrument integrated wet and dry dispersion test in one, successfully resolved the problem of dry and wet technology integration, realize one key to switch.
2) Intelligent full automatic operation system and manual operation, freely choose.
Choose automatic mode, very easy and simple to learn,support one key operation.
3) Optical Path System patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.
4) Automatic Optical path alignment System,
which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.
5) Full built-in Sample dispersion system.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.
6)Instrument Software
Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.
4. Software Function:
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
2,Statistic Method
Volume Distribution, Quantity Distribution
3,Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
4,User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
5,Test Report
Word, Excel,Photo( Bmp), Text etc.
6,Multi-language Support
Chinese&English (Others are available)
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
5. Application:
Winner2308 widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.
6. Standard Accessories list:
NO. | Items | Quantity | Unit | Remark |
1 | Winner2308 laser particle size analyzer | 1 | Set |
|
2 | Software | 1 | Set |
|
3 | Software key | 1 | PCS |
|
4 | Standard sample | 1 | Bottle |
|
5 | Power cable | 1 | PCS |
|
6 | Communication cable | 1 | PCS |
|
7 | Sample cuvette | 1 | PCS |
|
8 | Screwdriver | 2 | PCS |
|
9 | Wrench | 3 | PCS |
|
10 | Draining water pipeline | 1 | PCS |
|
11 | Standard sample pipeline | 1 | Set |
|
12 | Clean mirror paper | 3 | PCS |
|
13 | Clean mirror card | 1 | PCS |
|
14 | Sample cuvette brush | 2 | PCS |
|
15 | Spoon | 2 | PCS |
|
16 | 2A fuse | 5 | PCS |
|
17 | Quality certificate | 1 | PCS |
|
18 | Warranty Card | 1 | PCS |
|
19 | Manual | 1 | PCS |
|
7. Patents:
Winner 2308 Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
3 dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2








