Waste Water Source Heat Pump
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Water Heaters
Iljin E-Plus Co., Ltd.
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
12
Product name | Waste Water Source Heat Pump | Certification | - |
---|---|---|---|
Category | Water Heaters | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | 84186 |
Product Information
Waste Water Source Heat Pump
Product Overview
A heat pump system that recovers heat from waste water and supplys the recovered heat to the production of cold/hot water and cooling/heating system
Features
- Production of hot or cold water using waste water discharged from public bath or factory, without any environmental contamination; the energy saving system promoted by the nation.
- Much economical than oil or city gas (by 70-50%)
- Safe system free of risk of explosion that exists with oil and gas
- Excellent economical system as it utilizes waste heat
- Shorter the term of return on investment compared to other systems
Application
- Applicable to any sector that generates waste water and requires hot water such as Sauna, Golf club, Eel farm, Dyeing factory
Specification of Waste Water Source Heat Pump(IWM-12B Series)
Model
|
IWM-12B-34
|
IWM-12B-38
|
IWM-12B-51
|
IWM-12B-67
|
||
Performance
|
KW
|
117.79
|
133.6
|
180.47
|
235.7
|
|
Kcal/h
|
101,300
|
114,900
|
155,200
|
202,700
|
||
USRT
|
33.5
|
38
|
51.32
|
67.03
|
||
Power Consumption
|
KW
|
32
|
38
|
50
|
58
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||
Compressor Capacity
|
HP
|
30
|
36
|
48
|
56
|
|
Dimension
|
Length
|
mm
|
1,200
|
|||
Height
|
1,940
|
|||||
Depth
|
760
|
|||||
Compressor
|
Type
|
Scroll type
|
||||
Quantity
|
2
|
4
|
||||
Operation Method
|
Direct-on-line
|
|||||
Volume Control
|
%
|
0~100%
|
||||
Refrigeration Ton
|
RT
|
10.7
|
12.36
|
16.48
|
19.68
|
|
Refrigerant
|
Type
|
R-22
|
||||
Control Method
|
Thermostatic expansion valve
|
|||||
Heat Exchanger at Load-side
|
Type
|
Brazed Plate type
|
||||
Circulation Volume
|
LPM
|
52.76
|
59.84
|
80.83
|
105.57
|
|
Piping(IN/OUT)
|
A
|
40
|
50
|
|||
Heat Exchanger
at Heat source -side
|
Type
|
Spiral Tube Type
|
||||
Piping(IN/OUT)
|
A
|
125
|
||||
Control
|
Temperature Control
|
Automatic inlet/outlet temperature control
|
||||
Operation Control
|
PCB
|
|||||
Weight
|
kg
|
450
|
500
|
600
|
680
|
|
Operational Condition
|
Supply side (entry) temp to be 28°C; discharge side (exit) temp to be 80°C; Waste water temp to be 25°C
|
|||||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
Specification of Waste Water Source Heat Pump(IWH-12A Series)
Model
|
IWH-12A-31
|
IWH-12AB-35
|
IWH-12A-48
|
IWH-12A-55
|
||
Performance
|
KW
|
108.41
|
124.57
|
169.3
|
194.53
|
|
Kcal/h
|
93,230
|
107,130
|
145,600
|
167,300
|
||
USRT
|
30.83
|
35.43
|
48.15
|
55.32
|
||
Power Consumption
|
KW
|
32
|
38
|
50
|
58
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||
Compressor Capacity
|
HP
|
30
|
36
|
48
|
56
|
|
Dimension
|
Length
|
mm
|
1,200
|
|||
Height
|
1,940
|
|||||
Depth
|
760
|
|||||
Compressor
|
Type
|
Scroll type
|
||||
Quantity
|
2
|
4
|
||||
Operation Method
|
Direct-on-line
|
|||||
Volume Control
|
%
|
0~100%
|
||||
Refrigeration Ton
|
RT
|
11.2
|
12.52
|
17.28
|
19.84
|
|
Refrigerant
|
Type
|
R-410A
|
||||
Control Method
|
Thermostatic expansion valve
|
|||||
Heat Exchanger at Load-side
|
Type
|
Brazed Plate type
|
||||
Circulation Volume
|
LPM
|
37
|
42.51
|
57.78
|
66.39
|
|
Piping(IN/OUT)
|
A
|
40
|
50
|
|||
Heat Exchanger
at Heat source- side
|
Type
|
Spiral Tube Type
|
||||
Piping(IN/OUT)
|
A
|
125
|
||||
Control
|
Temperature Control
|
Automatic inlet/outlet temperature control
|
||||
Operation Control
|
PCB
|
|||||
Weight
|
kg
|
410
|
510
|
560
|
590
|
|
Operational Condition
|
Supply side (entry) temp to be 28°C; discharge side (exit) temp to be 70°C; Waste water temp to be 25°C
|
|||||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
Specification of Waste Water Source Heat Pump(IWB-12BA Series)
Model
|
IWB-12BA-62
|
IWB-12BA-74
|
IWB-12BA-100
|
IWB-12BA-117
|
||
Performance
|
KW
|
218.6
|
260
|
353.02
|
413.14
|
|
Kcal/h
|
188,000
|
223,600
|
303,600
|
355,300
|
||
USRT
|
62.17
|
73.94
|
100.4
|
117.49
|
||
Power Consumption
|
KW
|
56
|
66
|
88
|
104
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||
Compressor Capacity
|
HP
|
64
|
72
|
96
|
112
|
|
Dimension
|
Length
|
mm
|
1,700
|
|||
Height
|
1,940
|
|||||
Depth
|
1,000
|
|||||
Compressor
|
Type
|
Scroll type
|
||||
Quantity
|
4
|
4
|
8
|
8
|
||
Operation Method
|
Direct-on-line
|
|||||
Volume Control
|
%
|
0~100%
|
||||
Refrigeration Ton
|
RT
|
21.9
|
24.88
|
33.76
|
39.52
|
|
Refrigerant
|
Type
|
1st
|
R-22
|
|||
2nd
|
R-410A
|
|||||
Control Method
|
Thermostatic expansion valve
|
|||||
Heat Exchanger at Load-side
|
Type
|
Brazed Plate type
|
||||
Circulation Volume
|
LPM
|
74.6
|
88.73
|
120.48
|
140.99
|
|
Piping(IN/OUT)
|
A
|
40x4EA
|
50x4EA
|
|||
Heat Exchanger at Heat source- side
|
Type
|
Spiral Tube Type
|
||||
Piping(IN/OUT)
|
A
|
150
|
||||
Control
|
Temperature Control
|
Automatic inlet/outlet temperature control
|
||||
Operation Control
|
PCB
|
|||||
Weight
|
kg
|
640
|
770
|
910
|
1,050
|
|
Operational Condition
|
Supply side (entry) temp to be 28°C; discharge side (exit) temp to be 70°C; Waste water temp to be 25°C
|
|||||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
Specification of Waste Water Source Heat Pump(IWK-12C Series)
Model
|
IWK-12C-60
|
IWK-12C-74
|
||
Performance
|
KW
|
209.65
|
260.47
|
|
Kcal/h
|
180,300
|
224,000
|
||
USRT
|
59.62
|
74.07
|
||
Power Consumption
|
KW
|
53
|
64
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||
Compressor Capacity
|
HP
|
50
|
60
|
|
Dimension
|
Length
|
mm
|
1,450
|
|
Height
|
1,750
|
|||
Depth
|
1,000
|
|||
Compressor
|
Type
|
Scroll type
|
||
Quantity
|
1
|
|||
Operation Method
|
Y-
|
|||
Volume Control
|
%
|
0~100%
|
||
Refrigeration Ton
|
RT
|
17.35
|
19.38
|
|
Refrigerant
|
Type
|
R-407C
|
||
Control Method
|
Thermostatic expansion valve
|
|||
Heat Exchanger at Load-side
|
Type
|
Brazed Plate type
|
||
Circulation Volume
|
LPM
|
111.3
|
138.27
|
|
Piping(IN/OUT)
|
A
|
50
|
||
Heat Exchanger at
Heat source-side
|
Type
|
Spiral Tube Type
|
||
Piping(IN/OUT)
|
A
|
150
|
||
Control
|
Temperature Control
|
Automatic inlet/outlet temperature control
|
||
Operation Control
|
PCB
|
|||
Weight
|
kg
|
980
|
1,030
|
|
Operational Condition
|
Supply side (entry) temp to be 28°C; discharge side (exit) temp to be 55°C; waste water temp to be 20°C
|
|||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Cha Joo, Yoon
- Address
- 126-6, Sincheon-ri, Hallim-myeon, Gimhae-si, Gyeongsangnam-do, Korea
- Product Category
- General Industrial Equipment
- No. of Total Employees
- 51-100
- Company introduction
-
Ceaseless challenge by Iljin E-Plus, this is only the beginning!
Since its inception, We, Iljin E-Plus has been leading the heat pump market in Korea while keeping the principle of 'Value Creation and Quality First through customer satisfaction backed up by technology and trust' despite of the continuous challenge over the last 20 years.
Now grown as a company specialized in general energy saving devices, the Company is about to soar up as a global entity based on its sustainable system and experience and reliability built up over the years.
We are building a technical partnership with local and overseas leading companies. We shall continue to meet the challenge to create a new myth as a general energy saving company.
Thank you.
C J Yoon/CEO
- Factory Information
-
Iljin E-Plus Co., Ltd.
- Main Product