Sea Water Source Heat Pump
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Water Heaters
Iljin E-Plus Co., Ltd.
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
12
Product name | Sea Water Source Heat Pump | Certification | - |
---|---|---|---|
Category | Water Heaters | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | 84186 |
Product Information
Sea Water Source Heat Pump
Product Overview
An eco-friendly heat pump system that recovers sensible heat from the sea water and supply the recovered heat to the heat/cool the water tank, or produce cold/hot water without using any fossil fuel thereby saving energy and reducing greenhouse gas
Features
- Significantly saving energy costs associated with heating and cooling of the water tank at eel farms and aquaculture farms
- Maintaining the optimum temperature by accurate temperature control for the growth of the young and live fishes
- Extended equipment life and easy maintenance with the titanium dual pipe and spiral tube heat exchanger
- Fitted with the aerification system to the heat source tank so as to generate air bubbles to remove sludge and optimize the heat transfer of the evaporator
- Ability to recover heat even from the low temperature heat source (up to 5°C)
Application
- Applicable to any sector that uses sea water as a heat source and requires hot water and heating/air-conditioning such as Land aquaculture, Mariculture, Offices near the sea shore, Commercial buildings, Motel, Sauna and so on
Specification of Sea Water Source Heat Pump(IWS-55A, 53A, 13A Series)
Model
|
IWS-55A-42
|
IWS-55A-55
|
IWS-55A-62
|
IWS-53A-39
|
IWS-53A-51
|
IWS-53A-76
|
IWS-13A-21
|
||
KITECH
|
IJS-30SE
|
IJS-40SE
|
IJS-50SE
|
IJS-DW140
|
IJS-DW180
|
IJS-DW260
|
IJS-BW75
|
||
Capacity
|
Heating
|
KW
|
147.88
|
191.72
|
216.34
|
137.5
|
180
|
265.5
|
74.5
|
USRT
|
42.06
|
54.52
|
61.53
|
39.1
|
51.19
|
75.51
|
21.19
|
||
Cooling
|
KW
|
147.15
|
182.3
|
203.8
|
111.2
|
176.5
|
207.4
|
|
|
USRT
|
41.85
|
51.84
|
57.96
|
31.62
|
50.2
|
58.98
|
|
||
Heating/cooling
|
KW
|
20.0/24.4
|
26.20/32.80
|
34.57/42.94
|
19.68/3237
|
26.68/32.37
|
37.37/42.77
|
21.92
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
||||||||
Refrigeration Cycle
|
Single
|
Dual
|
Single
|
Dual
|
Single
|
||||
Dimension
|
Length
|
mm
|
1,950
|
1,950
|
2,200
|
1,950
|
1,950
|
2,600
|
1,950
|
Height
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
||
Depth
|
1,900
|
1,900
|
1,900
|
1,000
|
1,000
|
1,000
|
1,000
|
||
Compressor
|
Type
|
Scroll type
|
|||||||
Quantity
|
2
|
1
|
|||||||
Operation Method
|
Y-
|
||||||||
Volume Control
|
%
|
0~100%
|
|||||||
Refrigeration Ton
|
RT
|
12.56
|
16.78
|
21.06
|
21.06
|
16.78
|
12.52
|
19.38
|
|
Refrigerant
|
Type
|
R-410A
|
|||||||
Control Method
|
Thermostatic expansion valve
|
||||||||
Heat
Exchanger at Load-side |
Type
|
Coaxial type
|
Brazed Plate type
|
||||||
Circulation Volume
|
LPM
|
450
|
500
|
600
|
450
|
500
|
600
|
70
|
|
Piping(IN/OUT)
|
A
|
75
|
100
|
75
|
100
|
50
|
|||
Heat
Exchanger at Heat source-side
|
Type
|
Coaxial type
|
Titanium Tube type
|
||||||
Piping(IN/OUT)
|
A
|
|
750
|
600
|
450
|
70
|
|||
Control
|
Temperature Control
|
4way proportional control valve
|
|||||||
Operation Control
|
PCB
|
||||||||
Weight
|
kg
|
1,100
|
1,300
|
1,500
|
900
|
1,100
|
1,200
|
600
|
|
Operational Condition
|
heating
|
Inlet of heat exchanger at load-side to be 15°C; Inlet of heat exchanger at heat source-side to be 15°C
|
|||||||
Operational Condition
|
cooling
|
Inlet of heat exchanger at load-side to be 25°C; Inlet of heat exchanger at heat-source-side to be 25°C
|
|||||||
Conditions for IWS-13A-21 are: water temperature at the inlet of heat exchanger at the heat-source-side to be 15°C; Inlet and outlet of heat exchanger at the load-side to be 45°C and 60°C |
Specification of Sea Water Source Heat Pump(IWSK-55C, 53C Series)
Model
|
IWSK-55C-54
|
IWSK-55C-59
|
IWSK-55C-64
|
IWSK-53C-55
|
IWSK-53C-70
|
IWSK-53C-75
|
||
KITECH
|
IJS-50SES
|
IJS-SD200
|
IJS-SD230
|
IJS-SDW195
|
IJS-56SDW
|
|||
Capacity
|
Heating
|
KW
|
189.1
|
205.69
|
224.9
|
192.9
|
244.23
|
261.86
|
USRT
|
53.78
|
58.5
|
63.96
|
54.86
|
69.46
|
74.47
|
||
Cooling
|
KW
|
172.5
|
190.67
|
211.4
|
120.4
|
187.04
|
207.5
|
|
USRT
|
49.06
|
54.22
|
60.12
|
34.24
|
53.19
|
59.01
|
||
Heating/cooling
|
KW
|
29.10/37.07
|
29.78/38.77
|
38.90/48.17
|
30.68/34.10
|
38.38/45.73
|
37.94/40.95
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||||
Dimension
|
Length
|
mm
|
2,600
|
2,600
|
2,600
|
2,600
|
2,600
|
2,600
|
Height
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
1,870
|
||
Depth
|
1,900
|
1,900
|
1,900
|
1,900
|
1,000
|
1,000
|
||
Compressor
|
Type & Quantity
|
Screw x 1
|
||||||
Operation Method
|
Y-
|
|||||||
Volume Control
|
%
|
0~100%
|
||||||
Refrigeration Ton
|
RT
|
17.35
|
19.38
|
|||||
Refrigerant
|
Type
|
R-407C
|
||||||
Control Method
|
Thermostatic expansion valve
|
|||||||
Heat
Exchanger at Load-side |
Type
|
Coaxial type
|
||||||
Circulation Volume
|
LPM
|
500
|
600
|
600
|
500
|
Heating:750
|
800
|
|
Cooling:600
|
||||||||
Piping(IN/OUT)
|
A
|
100
|
||||||
Heat
Exchanger at Heat source-side |
Type
|
Coaxial type
|
Titanium Tube type
|
|||||
Circulation Volume
|
LPM
|
600
|
700
|
700
|
600
|
Heating:850
|
800
|
|
Cooling:800
|
||||||||
Piping(IN/OUT)
|
A
|
100
|
80/150
|
|||||
Control
|
Temperature Control
|
4way proportional control valve
|
||||||
Operation Control
|
PCB
|
|||||||
Weight
|
kg
|
1,600
|
1,700
|
1,700
|
1,500
|
1,200
|
1,600
|
|
Operational Condition
|
heating
|
Inlet of heat exchanger at load-side to be 15°C;
Inlet of heat exchanger at heat source-side to be 15°C |
||||||
Operational Condition
|
cooling
|
Inlet of heat exchanger at load-side to be 25°C;
Inlet of heat exchanger at heat-source-side to be 25°C |
||||||
The above performance data have been obtained from an official certification institution (KITECH), and may vary depending on the conditions of the installation site. |
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Cha Joo, Yoon
- Address
- 126-6, Sincheon-ri, Hallim-myeon, Gimhae-si, Gyeongsangnam-do, Korea
- Product Category
- General Industrial Equipment
- No. of Total Employees
- 51-100
- Company introduction
-
Ceaseless challenge by Iljin E-Plus, this is only the beginning!
Since its inception, We, Iljin E-Plus has been leading the heat pump market in Korea while keeping the principle of 'Value Creation and Quality First through customer satisfaction backed up by technology and trust' despite of the continuous challenge over the last 20 years.
Now grown as a company specialized in general energy saving devices, the Company is about to soar up as a global entity based on its sustainable system and experience and reliability built up over the years.
We are building a technical partnership with local and overseas leading companies. We shall continue to meet the challenge to create a new myth as a general energy saving company.
Thank you.
C J Yoon/CEO
- Factory Information
-
Iljin E-Plus Co., Ltd.
- Main Product