Product name | Automatic Clean Agent Fire Suppression system | Certification | - |
---|---|---|---|
Category | Other Firefighting Equipment | Material | - |
Keyword | hfc 227ea , clean angent , extinguishing , hfc 125 | Unit Size | - |
Brand name | DK-125 | Unit Weigh | 0 mg |
origin | South Korea | Stock | 1000 |
Supply type | OEM | HS code | 381300 |
Product Information
This product is an automatic clean agent fire suppression system that uses HFC-125 fire extinguishing agent and detects a fire, using a fast-activating glass bulb type detector, and automatically activates to suppresses the fire in a fast manner.
In general, this product can apply to small spaces such as main distribution frame (MDF), electric pipe shaft (EPS), telecommunication pipe shaft (TPS), air duct (AD) and electronic equipment room.
We have two types of automatic clean agent systems, i.e. a multi-cylinder system and a single-cylinder system, one of which is selected, depending on the volume to protect with it.
The maximum protected volume is 100㎥.
We can manufacture automatic clean agent fire suppression systems on a custom-made basis, replacing HFC-125 with a variety of other clean agent fire extinguishing agents, including HFC-227ea and FK-5-1-12.
[ High Sensitivity ]
ESFR-type glass bulb, 68°C, as the detector
[ High Safety ]
By using the aluminum cylinders for premium products (DK-95 series), the weight of the product has been reduced by a minimum of 30%, compared with our competitors!
The safety of the product has been improved during installation and maintenance!
The risk of cylinder leakage has been reduced!
As the only component of gaseous automatic fire suppression systems, a safety plate has been used to prevent a safety accident from happening caused by the discharge of a fire extinguishing agent due to breakage of the detector during transportation and installation. (patent registered)
DK-95 Series
모델명 | DK-951 | DK-952 | DK-953 | DK-954 | DK-955 | |||||||
Extinguishing Agent | Name | HFC-125 | ||||||||||
Purity | Min. 99% | |||||||||||
Quantity | 9.5kg | 9.5kgX2 | 9.5kgX3 | 9.5kgX4 | 9.5kgX5 | |||||||
Filling pressure | 25bar @ 21℃ | |||||||||||
Total Weight | 15.9kg | 16.1kgX2병 | 16.1kgX3병 | 16.1kgX4병 | 16.1kgX5병 | |||||||
Cylinder | Material | Forged Aluminum(seamless) | ||||||||||
Color | Ivory | |||||||||||
Capacity | 11L | |||||||||||
Size | 165mm diameter / 729mm Height | |||||||||||
Fire detection | 68℃ glass bulb(fast type) | |||||||||||
Actuation | Stand alone | Multi interlock type | ||||||||||
Maximum coverage Volume | A,C Fire | 19.73㎥ | 38.88㎥ | 59.19㎥ | 78.92㎥ | 98.65㎥ | ||||||
B Fire | 14.08㎥ | 28.16㎥ | 42.24㎥ | 56.32㎥ | 70.4㎥ | |||||||
Maximum coverage Area | 1 row | 17.73㎡ (4.91m x 3.61m) | 17.73㎡X2 (4.91m x 3.61mX2) | 17.73㎡X3 (4.91m x 3.61mX3) | 17.73㎡X4 (4.91m x 3.61mX4) | 17.73㎡X5 (4.91m x 3.61mX5) | ||||||
2 row | 17.73㎡ (4.91m x 3.61m) | 17.73㎡ (4.91m x 3.61m) | 17.73㎡X2 (4.91m x 3.61mX2) | 17.73㎡X2 (4.91m x 3.61mX2) | ||||||||
Maximum coverage Height | 1 row | 4.5m | 4.5m | |||||||||
2 row | 9.0m | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
DK-161 Series
모델명 | DK-1611 | DK-1612 | DK-1613 | ||||
Extinguishing Agent | Name | HFC-125 | |||||
Purity | Min. 99% | ||||||
Quantity | 16.1kg | 16.1kgX2 | 16.1kgX3 | ||||
Filling pressure | 25bar @ 21℃ | ||||||
Total Weight | 30.2kg | 30.2kgX2병 | 30.2kgX3병 | ||||
Cylinder`` | Material | Steel(seam) | |||||
Color | Red | ||||||
Capacity | 20L | ||||||
Size | 230mm diameter / 735mm Height | ||||||
Fire detection | 68℃ glass bulb(fast type) | ||||||
Actuation | Stand alone | Multi interlock type | |||||
Maximum coverage Volume | A,C Fire | 33.45㎥ | 66.9㎥ | 100.00㎥ | |||
B Fire | 23.87㎥ | 47.74㎥ | 71,61㎥ | ||||
Maximum coverage Area | 1 row | 31.98㎡ (8.86m x 3.61m)
| 31.98㎡X2(8.86m x 3.61mX2) | 31.98㎡X3 (8.86m x 3.61Mx3) | |||
2 row |
| 31.98㎡ (8.86m x 3.61m) | 31.98㎡ (8.86m x 3.61m) | ||||
Maximum coverage Height | 1 row | 4.5m | 4.5m | ||||
2 row | 9.0m | ||||||
|
|
|
|
|
|
|
|
B2B Trade
Price (FOB) | Negotiable | transportation | Ocean Shipping |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | L/C,T/T | Shipping time | Negotiable |
DK Fire
-
3
- President
- Lee Daikyu
- Address
- 51-6 Yulsaengjungang-ro Daegot-myeon , Gimpo-si, Gyeonggi-do, Korea
- Product Category
- Fire Extinguisher
- Year Established
- 2012
- No. of Total Employees
- 1-50
- Company introduction
-
DKFIRE was established with the goal of achieving "Dream of Korean Fire Suppression Systems" in 2012.
Our main business is to develop and sell fire extinguishers and fire suppression systems using clean agent fire extinguishing agents such as HFC-227ea, HFC-125, FK-5-1-12, CO2, and inert gases.
We are specialized in developing, manufacturing, and supplying fire suppression systems which are appropriate for special hazards such as those places where existing regulatory fire suppression systems are neither suitable, nor applicable.
Specifically, we are devoted to developing special fire suppression systems which may best suit the fire protection of electric panels, CNC machines, 3D printers, small boats/ships, and automobiles.
In addition, we develop and supply custom-made fire suppression systems, based on the specifications which customers provide us with.
Our business also includes provision of consultation services on development of gaseous fire suppression systems.
- Main Markets
-
India
Indonesia
Japan
Kyrgyzstan
Philippines
Singapore
Tadjikstan
Taiwan
Turkmenistan
Viet Nam
- Main Product
Related Products
FIRE FIGHTER UNIFORM (T-Flame Guard)
Fire hunter / fire extinguishing patch for outlet
SMPS CASE
VR firefighting training system - NESTs National Emergency S
Sprinkler Head