- South Korea / 2009
FLOW COMPUTER
- ◾ Price: Negotiable
- ◾ MOQ: Negotiable
FLOW COMPUTER
- ◾ Price: Negotiable
- ◾ MOQ: Negotiable
-
Required Quantity
-
Brand name
-
Shipping / Lead TimeNegotiable / Negotiable
-
Keyword
-
Category
Specifications
| Size | 420 * 350 * 300 mm | Weight | 4 kg | Stock | - |
|---|---|---|---|---|---|
| Country of Origin | South Korea | ||||
| Production method | Negotiable | ||||
| Certification |
|
||||
| HS Code | 9026109000 | ||||
Trade Terms
| Payment Terms | T/T | ||||
|---|---|---|---|---|---|
| Price(FOB) | Negotiable | MOQ | Negotiable | ||
| Transportation | - | ||||
| Lead time | Negotiable | Shipping time | Negotiable | ||
Company
-
Country / Year Established
-
Membership
- VIP
Business typeManufacturer
-
Verified Certificate
-
6
-
6
-
Main Export Markets
-
Indonesia
-
Malaysia
-
Philippines
-
Thailand
-
Viet Nam
-
Product Description
Product Catalog / Brochure / Spec Sheet
The NF750 Steam and Gas Flow Computer incorporates the following compensation equations for gas and vapours:
Ideal Gas Law using temperature and pressure correction, but where compressibility correction is not required. General Gases where compressibility is calculated using the Redlich-Kwong¹ state equation. This equation is suitable for gases which have known properties, and information on common industrial gases is provided in the operating manual.
Natural Gas using the NX-19² equation to calculate super compressibility.
Steam Equations for both saturated and superheated steam. Mass and energy flow rates are calculated using standard equations to determine the specific weight and enthalpy of steam.
Inputs from a wide range of flowmeters are accepted, including vortex, turbine, orifice plate, averaging pitot tubes, wedges and target flowmeters. Also, where two differential pressure transmitters are used across an orifice or similar device, to increase the measured flow range, both DP transmitter inputs are accepted and scaled separately with automatic crossover.
1. Model : NF750
2. Type : Panel Mounting
3. Input : Flow .- Analog & Pulse (From Flowmeter)
Temp. - Pt 100 ohm at 0 deg℃ (From R.T.D)
Press. - Analog 4~20mA (From R.T.D)
* Note : Temp. and Press. compensated function.
4. Output : Analog 4~20mA & Pulse & RS232/422/485
5. Power : AC 110/220V