Specifications

Size - Weight - Stock -
Country of Origin China
Production method Negotiable

Trade Terms

Payment Terms L/C, T/T
Price(FOB) Negotiable MOQ Negotiable
Transportation -
Lead time Negotiable Shipping time Negotiable

Company

  • Country / Year Established
    • China
    • China / 2012
  • Membership
    • BIZ
    Business type
    Manufacturer
  • Verified Certificate
    • 8
  • Main Export Markets
    • Armenia Armenia
    • Austria Austria
    • Bahrain Bahrain
    • Bosnia-Herzegov Bosnia-Herzegov
    • Brunei Brunei

Product Description

 

High altitude low pressure simulation test chamber
Altitude Chamber For Sale
Altitude Test Chambers
Temperature testing at altitudes up to 100,000 feet.
Grande can provide custom-built chambers for simultaneous testing of temperature and low-pressure altitude conditions. Two common applications are:
Testing of avionics or other aerospace equipment to simulate actual conditions it might experience.
Simulation of high-altitude conditions like might be found in mountainous regions.
NOTE: Altitude test chambers are custom systems, and differing requirements may significantly change the cost and utility requirements. Please let Grande know as much detail as possible about your anticipated testing specification/method, and we can provide you with a tailored system for your requirements.
Features
Temperature range from -70 to 200°C
Altitude range from ground to 100,000 feet
Optional humidity control when altitude system is off
Chamber interior size specified by customer
Automatic altitude control, integrated with temperature controller—No manual setting of altitude level!
Vacuum pump sized for climb/dive rate required by application
Viewing window and cable ports available
Corresponding Standard of the Temperature and Humidity Test Chamber:
1.GB10590-89  Low-temperature and low atmospheric pressure testing condition
2.GB10591-89 High-temperature and low atmospheric pressure testing condition
3. GB11159-89 low atmospheric pressure technical condition
4. GB/T2423.25-1992 Low-temperature and low atmospheric pressure test chamber
5. GB/T2423.26-1992 High-temperature and low atmospheric pressure test chamber
6.GJB150.2-86 High-temperature and low atmospheric pressure(Altitude) test
7,IEC60068-2-1.1990 Testing methods of Low-temperature test chambers
8,IEC60068-2-2.1974 Testing methods of High-temperature test chambers
9,IEC-540
10,ASTM D2436
11,JIS K7212
12,DIN 50011
13,BS2648
14,Mil-Std 202G (conditions 105C, A/B/C/F)
15,Mil-Std 810G (condition 500.5)
16,IEC 60068-2-39
17,IEC 60068-2-40
18,RTCA/DO-160F
19,JIS W 0812
Technical parameters:
Model No  GATC-150 GATC-225 GATC-408 GATC-800 GATC-1000
Working room(L) 150 225 408 800 1000
Inner chamber size(mm)W*H*D 500*600*500 500*750*600 600*850*800 1000*1000*800 1000*1000*1000
Exterior chamber size(mm)W*H*D 1000*1600*1400 1000*1750*1500 1100*1850*1700 1500*2000*1700 1850*1600*2250
Packaging volume(CBM) 3 3.5 4.5 5.5 6
G.W.(KGs) 320 350 400 600 700
Testing temperature range -80°C,-73°C,-60°C, -40°C, -20°C, 0°C~+150°C, +200°C (300°C)
Performance Temperature range -65℃~150℃
Temp.fluctuation ±0.5℃(Room pressure)
Temp.accuracy ±2.0℃(Room pressure)
Heating up time ≤60min(+20℃~+150℃、RP、No-Load)
Cooling down time ≤45min(RP) ≤60min(RP) ≤90min(RP)
Pressure range RP~0.5kPa
Pressure control tolerance ±0.1kPa(≤2kPa),±5%(2kPa~40kPa),±2kPa(≥40kPa)
Depressurization time ≤20min ≤25min ≤30min ≤45min ≤50min
Working environment Temp:+5℃~+35℃;Humidity:≤90%RH;Airpressure:86-106kPa
Material Exterior chamber materia Stainless steel plate+ powder coated
Inner chamber materia SUS#304 stainless steel plate
Insulation Material PU Fiberglass wool
System Air circulation system Cooling fan
Heating System SUS#304 stainless steel high-speed heater
Humidification system Imported compressor,Tecumseh compressor(or Bizer Compressor),finned type evaporator,air(Water)-cooling condenser
Dehumidification system ADP critical dew point cooling/dehumidifying method
Controlling system TEMI880,990
Power kw 8 10 12 15 20
Water supply Water temperature:≤30℃;water pressure:0.2~0.4MPa;flow rate:≥10T/h 
Other components Specimen holders 2pcs,electrical wire 1pc(3M),pressure testing port.
Safety protection device Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.
Power supply AC 3Ψ380V 60/50Hz
Customized service Welcome to Non-standard,Specail requirements,OEM/ODM orders.
Optional accessories
1,Low Humidity and Dehumidifying sytstem.
2,Inner glass door with manual operating ports.
3,Temp./Humi.Recorder.
4,Pure water treatment device
5,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
6,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system.

 



Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more