full automatic true density analyzer G-DenPyc 2900 analyzer

full automatic true density analyzer G-DenPyc 2900 analyzer


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
China
Brand name
Gold APP Instruments
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
adsorption, true density tester, gas pycnometer, pycnometer
Category
Other Analyzers

Gold APP Instruments Corporation China

Membership
BIZ
Country / Year Established
China China / 2007
Business type
Manufacturer
Verified Certificate

7

Product name full automatic true density analyzer G-DenPyc 2900 analyzer Certification -
Category Other Analyzers Ingredients -
Keyword adsorption , true density tester , gas pycnometer , pycnometer Unit Size 70.0 * 90.0 * 70.0 cm
Brand name Gold APP Instruments Unit Weigh 70 kg
origin China Stock -
Supply type - HS code 90318090

Product Information

G-DenPyc 2900 gas pycnometer true density analyzer introduction

 

A gas pycnometer operates by detecting the pressure change resulting from displacement of gas by a solid object. Expanding a quantity of gas at known pressure into an empty chamber and measuring the pressure establishes a baseline. Then a sample is placed in the chamber and the chamber is resealed. The same quantity of gas at the same pressure is again expanded into the sample chamber, and the pressure is measured. The difference in the two pressure combined with the known volume of the empty sample chamber allows the volume of the sample to be determined by way of the gas law. The accuracy and precision of the gas pycnometer in determining density is good, but the method relies greatly on the cleanliness of the sample material and purity of the analysis gas. In this case, Gold APP Instruments had explored a smart sample preparation degasser for materials handle, can guarantee to gain the "cleanliness" testing data.

 

 editorimg

G-DenPyc 2900 gas pycnometer true density analyzer application

 

Apply to research and quality control for below materials: ceramic, catalysts, filter medium, nuclear fuel, oil & chemical industry, soil, fertilizer, carbon black, hard coke, fiber, minerals, pharmacy, cosmetics, cement, powdered foodstuff, desiccant (drying agent), powdered metal, ion exchange resin, silicon gel, alumina, titanium dioxide, solid foam etc.

 

 

G-DenPyc 2900 gas pycnometer true density analyzer parameters

 

  1. Analysis Method: Volume displacement method/gas expansion principle

  2. Versatility: true (also terms as real, absolute, apparent or skeletal) density analysis, rigid foam materials’ percentage of open/closed spaces analysis

  3. Experimental Pressure: external vacuum pump is available, can adopt negative pressure (0-1Bar) or positive pressure (1-2Bar) two modes to analysis

  4. Accuracy: accuracy ±0.02%, repeatability ±0.01%, resolution can reach 0.0001 g/cc

  5. Sample Ports: three samples analysis ports

  6. Sample Container: provide 3ml, 10ml, 11ml and 70ml standard containers, also can customize any volume containers from 1-500ml.

  7. Pressure Accuracy: imported high-precision pressure transducer, accuracy can reach 0.05% F.S., stability 0.025% F.S.

  8. Adsorbate Gas: high purity Helium or air or Nitrogen

 editorimg

 

G-DenPyc 2900 gas pycnometer true density analyzer features

 

  1. Data Reduction: high-precision PρT gas density calculation model eliminates measurement errors caused by non-ideality gas state, can increase analysis accuracy

  2. Thermostatic System: analysis modules designed with thermostatic system can control temperature up and down easily, also hold modules stay at the best temperature(25 C) which can restrain transducer reading’s temperature drift and keep system temperature uniformity; System can maintain temperature at a fixed value for some fixed-temperature-required samples

  3. Control System: programmable logic controller (PLC) system obtains high integration and strong anti-interference, software operated fully automated analysis enables freely choose of multi measurement modes

  4. Analysis Management: programmable built-in system, touch screen, USB type external keyboard and mouse, operated by connecting to computer is available

  5. Manifolds System: patented V-Sorb monolithic manifolds system can improve sealing performance and reduce dead space largely, enhance system temperature’s uniformity and anti-interference ability, all lead to a high accuracy and repeatability data

  6. Splash-proof Measures: installed with a detachable filter in sample cell’s bottom, can prevent samples be suctioned into manifolds; inputting gas from bottom of cavity can avoid samples splash and software controlled H-Sorb two-stage-stepping mode further ends splash happening

  7. Sample Container: 50mm (diameter) and 180ml (500ml is available) big cylinder sample cell is convenient for samples filling; Exclusive G-DenPyc filling technology supports to choose different volumetric aluminum blocks to fill cell instead change other sizes cells according to samples’ volume, this innovative method realizes minimal free space in cells and improve experiment accuracy

 

 

 

Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Gold APP Instruments Corporation China

Country / Year Established
China China / 2007
Membership
BIZ
Business type
Manufacturer

7

President
xia pan
Address
room 811, new material building, No. 7th, Fenghui Mid Rd., Haidian Dist, Beijing 100094
Product Category
Other Analyzers
Year Established
2007
No. of Total Employees
51-100
Company introduction
<p>

Gold APP Instruments (www.jinaipu.com), expert in gas sorption analyzers, is a high technology and originality corporation located in Zhongguancun, Beijing High-tech Industry Zone, where gathered numerous national famous universities and research laboratories.

 

Gold APP Instruments analyzers cover F-Sorb X400CE series based on flow gas adsorption principle and V-Sorb X800 series rely on static volumetric adsorption for surface area and pore size analysis. Further, an extremely sophisticated high pressure gas sorption analyzer H-Sorb X600 series and the revolutionary gas pycnometer true density analyzer G-DenPyc X900 series left other components far behind. Gold APP Instruments scientists have revolutionized measurement techniques and designed instrumentation to enable the accurate, precise, and reliable characterization of powdered and porous materials: battery and fuel cell materials, heterogeneous catalysts, pharmaceuticals, ceramics, carbons, zeolites, projectile propellant, cosmetics, aerospace, nanotubes, medical implants, pigments and foodstuffs, indeed any solid whose performance depends on some interaction with its surroundings through its surface.

Main Markets

Australia Australia

Canada Canada

China China

India India

Nigeria Nigeria

Saudi Arabia Saudi Arabia

Singapore Singapore

South Korea South Korea

Thailand Thailand

U.S.A U.S.A

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more