X-Ray
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- X-Ray Equipment
Sehwa Medical Systems Co., Ltd.
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
16
Product name | X-Ray | Certification | - |
---|---|---|---|
Category | X-Ray Equipment | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Diagnostic X-ray Generators
500mA/125kVp, 500mA/150kVp,
600 mA/150kVp R/F X-ray Generator
- Microprocessor control system!!
- Digital display & membrane switch!!
- 72 preset anatomical programs!!
- Self-diagnosing function!!
- Good design & easy handling!!
SMS-525-MF
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 35KVA
- Maximum output ratings
- 100mA at 100 KVP
- 80mA at 125 KVP - Indication meter :
- KVP, Time, mA, mAs
- LED Lamp full indication - Radiographic mode
- mA setting : 50mA to 500mA
- KVP setting : 45KVP to 125KVP
- Time setting : 1/120 to 5sec. (50 steps) - Spot radiographic mode
- mA setting : 150mA to 300mA
- KV setting : 45KVP to 125 KVP
- Time setting : 1/120 ~ 5sec (50steps) - Fluoroscopic mode
- mA setting : 0.5mA to 3.0mA (5steps)
- KV setting : 50KVP to 120 KVP
- Maximum radiation time : 5min. - Anatomical mode
- 72 preset anatomical programs. - Self-diagonosing function
- Over load. Back up, Error code - Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- maximum output ratings
- 500mA at 100KVP
- 300mA at 125KVP - Fluoroscopy output ratings
- 0.5mA at 120KVP
- 3mA at 125 KVP - Filament transformer
- small output : 100V : 16V
- large output : 100V : 24V - High tension silicon rectification
- Maximum output capacity : 35KVA
SMS-550-MF
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 45KVA
- Maximum output ratings
- 500mA at 100 KVP
- 300mA at 150 KVP - Indication meter :
- KVP, Time, mA, mAs
- LED Lamp full indication - Radiographic setting mode
- mA setting : 50mA to 500mA
- KVP setting : 45KVP to 150KVP
- Time setting : 1/120 to 5sec. (50 steps) - Spot tradiographic mode
- mA setting : 150mA to 500mA
- KV setting : 45KVP to 125KVP
- Maximum radiation time : 5min - Anatomical mode
- 72 preset anatomical programs. - Self-diagonosing function
- Over load. Back up, Error code - Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- Maximum output ratings
- 500mA at 100KVP
- 300mA at 150 KVP - Fluoroscopy output ratings
- 0.5mA at 120KVP
- 3mA at 100KVP - Filament transformer
- small output : 100V : 16V
- large output : 100V : 24V - High tension silicon rectification
- maximum output capacity : 45KVA
SMS-650-MF
Generator
- Micom control & digital display
- Power supply : 220V, 50/60Hz, single phase
- Pwer consumption : 50KVA
- Maximum output ratings
- 600mA at 100 KVP
- 300mA at 150 KVP - Indication meter :
- KVP, Time, mA, mAs
- LED Lamp full indication - Radiographic setting mode
- mA setting : 50mA to 600mA
- KVP setting : 45KVP to 150KVP
- Time setting : 1/120 to 5sec. (50 steps) - Spot radiographic mode
- mA setting : 150mA to 600mA
- KV setting : 45KVP to 125KVP
- Time setting : 1/120 to 5sec (50steps) - Fluoroscopic mode
- mA setting : 0.5mA to 3.0mA
- KV setting : 45KVP to 125KVP
- Maximum radiation time : 5min - Anatomical mode
- 72 preset anatomical programs. - Self-diagonosing function
- Over load. Back up, Error code - Dimension (W x D x H)
- 630 x 400 x 820mm
H/V Transformer
- Insulating oil-filled unit
- maximum output ratings
- 600mA at 100KVP
- 300mA at 150KVP - Fluoroscopy output ratings
- 0.5mA at 120KVP
- 3mA at 100KVP - Filament transformer
- small output : 100V : 16V
- large output : 100V : 24V - High tension silicon rectification
- Maximum output capacity : 50KVA
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Young-pyo, Kim
- Address
- 621-14 Docheon-dong, Gwangsan-gu, Gwangju
- Product Category
- Medical Devices,X-Ray Equipment
- Company introduction
-
Hello. I'm Kim Youngpyo, president of Sehwa Medical System Co., Ltd.
I am grateful for your unchanging trust and encouragement.Sehwa Medical System develops and manufactures diagnostic X-ray systems.
With a corporate motto of technological development, unity and full responsibility,Sehwa Medical System is making its best effort to become the world's greatest specialist in X-ray equipment. With international technology and the trust of customers
Sehwa will continue to maintain a special relationship with you.
- Main Markets
-
Bulgaria
Japan
Mongolia
Thailand
Viet Nam
- Main Product