Petro Loading Counter with Temperature Compensation
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Electrical Equipment
Flos Korea
- Country / Year Established
- South Korea /
- Business type
- Others
- Verified Certificate
-
15
Product name | Petro Loading Counter with Temperature Compensation | Certification | - |
---|---|---|---|
Category | Electrical Equipment | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Feature
- Gross, net, weight batch count / gross, net/ gross and net
- Temperature compensation to API Tables
- gross or net scaled pulse output
- Basic 1-channel(Option 2-Channel loading)
- Dual data communication port with protocol matching
- Fully isolated External Input and Output
Over View
The PCL600 Series batch controllers use temperature correction to calculate the volumetric flow for liquids at standard reference conditions. The PCL600 Series is ideally suited to custody transfer applications and includes the API/ASTM equations covering general petroleum products and LPG. The PCL600 Series is direct RTD input or 4-20mA temperature input.
General
Display | Main : Large 2-line x 20-character LCD With LED B/L Sub : Small 2-line x 20-character LCD With LED B/L |
Display Update Rate | 0.25-second |
Decimal Points | Fully programmable for Rate and Total |
Time Base | The Rate can be displayed in unit per second, per minute, per hour or per day |
Data Retention | Set up parameters and totals stored in non-volatile memory with 10 years retention |
Operation Temperature | -25°C to 60°C |
Power | AC110V/ 220V Selectable(50/60Hz) |
Transducer Supply | 12V or 24V selectable, 100mA max |
Flow Inputs
Frequency(Pulse) Input | |
Number Of channel | 2-Channel |
Frequency Range | 0.5 to 10 kHz Max |
Signal Type | open collector, reed switch, voltage and current pulse |
K-factor Range | 0.0001 - 50000.0000(the pulse per units) |
Analog Input | |
Number Of channel | 2-Channel |
Inputs | 4-20 mA or 1-5V option |
Input Impedance | Current 250 ohms Voltage 10K ohms |
Accuracy | 0.05% |
Span | 0.0001 to 50000.0000 |
Zero | 0.0000 to 50000.0000 |
Cut-off Point | A low flow rate cut-off can be programmed below which flow is not registered. The cut-off is programmed as a percentage of span relationship Linear or square root. |
Temperature Input
RTD Input | |
Number Of channel | 2-Channel |
Type | Platinum PT100(DIN) |
Temperature Range | -100°C to +200°C(Refer to the ordering information for detail) |
Accuracy | 0.1°C |
Linearity | The non-linearity of the RTD is internally compensated for. |
Analog Input | |
Number Of channel | 2-Channel |
Inputs Impedance | 250 ohms |
Measurement Range | -100°C to +200°C |
Accuracy | 0.05% |
Digital Input
Channel | 6-Channel |
Function | Open collector Input For External switch, Earth Device, Aux pulse input. etc |
Pulse Width | 10 ms(negative going pulse) |
Nominal Input Voltage | 12VDC |
Maximum Input Voltage | 12VDC |
Valve Control Output
Function | Two stage valve control Digital valve control |
Relay Type | AC Solid-State-Relay or Mechanical Contact-Relay |
Load Voltage | 90-240VAC or 250VAC/30VDC |
Max. Current | 1.5 Amps or 10A |
4-20mA Output
Channel | 2-Channel |
Function | Outputs flow rate in gross volume, net volume, mass or energy, The 4 and 20 mA points can be programmed to provide a fully scaled output. |
Resolution | 12-bit |
Accuracy | Better than 0.025% |
Maximum Load | 500 ohms internally powered. 950 ohms from external 24V dc. |
Isolation | Output is isolated. |
RS232/422/485
Type | Both RS232 and RS422/485 are provided.(Note : When using the RS422/485, multi drop communication can be implemented with up to 32 instruments connected to a common bus. |
Communication Channel | 2-Channel |
Isolation | Communication is optical isolation |
Function | Printer and computer protocols are fully programmable. |
Printer | A print is initiated on each reset or at a programmable time interval. |
Computer | An ASCII based protocol enable all display parameters to be read and the totals to be reset. |
Baud Rate | 1200 to 19200 BPS |
Data Bit | 8-bit |
Parity Bit | None |
Time | A real time clock is provided to give time and date on each output. |
Digital Output
Function | Open collector output with a pulse produced on each increment of the accumulated total(gross, net, mass or energy). |
Pulse Width | 10ms(negative going pulse) |
Duty Cycle | 49 pulses/sec. Max. |
Channel | 5-Channel |
Output | Current sinking output transistor 50ma, 30vdc max.(Pulse output is suitable for driving remote counter or PLC's) |
Enclosure
Explosion proof | |
Outside Dimension | 270mm(H) x 290mm(W) x 280(D) Notice : H is not fixed |
Mounting Dimension | 90mm(H) x 83mm(W) x M8 Bolt |
Classification |
Division 1, Class I Group-A, B,C,D |
Application
- Truck Loading
- Railcar Loading
- Chemical Loading
- LPG, Lube Oils
- Barge Loading
- Shipping Docks
- Bulk plants
System
Modeling
MODEL | Description | |||||
PCL600- | Petro loading Controller | |||||
Temperature | N A R |
No Option 4-20mA Analog Temperature Input Pt 100 Ohms RTD Input |
||||
Channel |
1 |
One arm loading(STD) Two arm loading(OPTION) |
||||
Analog Output | 0 1 2 |
No option 4-20mA output 1 channel 4-20mA output 2 channel |
||||
Case | E | X |
Explosion proof |
Dimension
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- SHIN YI RAE
- Address
- #1119 Woolim Lions Valley II 680 Gasan-dong, Geumcheon-Gu, Seoul, Korea
- Product Category
- Wires & Cables
- Company introduction
-
FLOS KOREA have been doing business for over 20 years as one of the leading
Manufacturers and exporters of Flow Instruments in Korea.Korean Customers depend on FLOS KOREA for quality Flow Instruments products
Which are simple to operate, an generate reliable results for all their
Process requirements.
Sophisticated testing equipment ensures that every Flow controller, Flow Transmitter
and Flow Computer, Batch Controller manufactured meets our highest standards.Engineered to provide reliable, accurate information, FLOS KOREA instrument are
Used in applications form Flow controller and Automate Factory.
We are also proud to offer easy-to-use instrumentation, ensuring simple installationAnd minimal maintenance.
- Main Product
Related Products
[M2I Corporation] XTOP12TS-SA HMI TOUCH PANEL M2I TOP
IP67 waterproof Terminal Block Box 4P Knock-out
High-end DAC and preamplifier – sDP-1000
LCD Touch Panel
Magnetic Contactor (MC)