DCM03 Reflectance Integrated SPO2 Blood Sensor

DCM03 Reflectance Integrated SPO2 Blood Sensor


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
Category
Wires & Cables

APMKorea

Membership
PRO
Country / Year Established
South Korea South Korea / 2008
Business type
Manufacturer
Verified Certificate

16

DUNS

Product name DCM03 Reflectance Integrated SPO2 Blood Sensor Certification -
Category Wires & Cables Ingredients -
Keyword - Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

The idea of using light reflection instead of light transmission in clinical oximetry shows that SpO2 can be monitored by measuring the amount of light reflected from the tissue. The idea of using skin reflectance spectrophotometry marked a significant advancement in the noninvasive monitoring of SpO2 from virtually any point on the skin surface.

The intensity of the back scattered light from the skin depends not only on the optical absorption spectrum of the blood but also on the structure and pigmentation of the skin. SpO2 is measured be analyzing the pulsatile componens of the detected red and infrared plethysmograms which make use of reflected light intensities. The light from the LEDs enters the tissue, is scattered by both the moving red blood cells and the nonmoving tissue, and a part of this back scattered light is detected by the photodiode.

The output of photodiode is processed by the pulse oximeter, and measures the SpO2 of the pulsatile blood. In reflectance pulse oximetry, the LEDs and the photodiode are placed on the same side of the skin surface as shown below. Normally the reflectance probe is placed on the forehead or temple, but is not restricted to only those two places. Reflectance probes can be used to measure arterial oxygen saturation at virtually any place the human body where the probe can be placed.

DCM01 DCM02 developed by APMKorea is a sensor integrated built in LEDs and PD together with optimized properly against such trade-off to get proper parameters. Furthermore DCM01 DCM02 has SMD type package so that user could interconnect easily wire or flip bonding into your set.

This reflectance sensor can be placed on the body where you can expect light reflection due to tissue.

Features

  • Integrated Dual Emitter and Photo Detector
  • Dual Red and IR LED Matched to SPO2
  • Chip on Board Package

Applications

  • Reflective Oximeter Probes
  • Blood Analysis
  • Medical Instrumentation
  • Radiometric Instrument

Absolute MAX. Ratings(Ta=25°C unless otherwise noted)

Symbol
Parameter
Max. Rated Value
Units
PD
Power Dissipation
120
mW
IF
Continuous Forward Current
50
mA
IFR
Peak Forward Current
100
mA
VR
Reverse Voltage
5
V
T stg
Storage Temp.
-20~+85
°C
T opr
Operating Temp.
-20~+85
°C
T sd
Soldering Temperature *1
240
°C
*1. Test Condition : t<3s

Characteristics(Ta=25°C unless otherwise noted)

Symbol
Characteristic
Components
Test Condition
Min
Typ
Max
Units
VF
Forward Voltage
LED1
IF=20mA
 
1.9
2.2
V
LED2
 
1.3
1.5
PD
IF=10mA
0.2
 
1.3
IR
Reverse Breakdown Current
LED1, LED2
VR=5V
   
10
uA
P O
Output Power
LED1
IF=20mA
 
2
 
mW
LED2
 
2
 
λ PEAK
Peak Wavelength
LED1
IF=20mA
650
660
670
nm
LED2
880
905
910
PD
   
940
 
Δλ
Half Wave Width
LED1
IF=20mA
 
30
 
nm
LED2
 
60
 
V BR
Reverse Breakdown Voltage
PD
IR=100uA
35
   
V
I D
Reverse Dark Current
V R=10V
   
20
nA
I L
Light Current
1mW, 940nm
 
45
 
uA
S
Spectral Response Rrange
 
400
 
1050
nm
CJ
Junction Capacitance
VR=3V, f=1MHz
 
44
 
pF

PPG(Photo Plethysmogram) Characteristic

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

APMKorea

Country / Year Established
South Korea South Korea / 2008
Membership
PRO
Business type
Manufacturer

16

DUNS

President
shoon Han
Address
52 Songnimro, Yuseong-gu, Daejeon, Korea
Product Category
Sensors
Year Established
2008
No. of Total Employees
1-50
Company introduction

Shoon Han, CEO/owner has established APM (Advanced Photosensor Manufacturing) Korea on 9th, September 2008.

He had experience for 25years in semiconductor industry.

Company registrered Korea government as firm of manufacturer of electronics with certificate No. 305-27-21270 .

Joined the member of the KITA (Korea International Trade Association) Register No. 16118892.

Shipped SPO2 oximetry optic sensor for medical device customers in Germany, India, Indonesia, Singapore, Turkey and Korea. June 2009~.

Developed reflective PPG sensor, providing new idea and varial applications for medical device customers in Singapore, Germany, Ukraine, India. March 2010~.

Joined New Exporters 300 as a member, consulted by KITA (Korea International Trade Association). 23rd March 2010.

Shipped SPO2 sensor chips for medical device customers in Switzerland and Brazil May 2010~.

Joined Exporter Club as a member, consulted by SMBA (Small & Medium Business Administration). 18th May 2010.

Shipped PPG sensor for medical device customers in Colombia 20th May 2010~.

Presented at the Technology Road Show in Shanghai & Beijing China 6~10th Sep. 2010

Shipped Refective PPG sensor to Japan 15th Sep. 2010~.

Shipped SPO2 oximetry sensor for medical device customers in Shanghai China Dec 3rd 2010~.

Shipped PPG sensor chips for medical device customers in Uruguay 11th Dec 2010~.

Shipped Refective PPG sensor for medical device customers in South Africa 13rd Dec 2010~.

Assign a distributor for Shenzhen China medical market 13rd Dec 2010~.

Shipped SPO2 oximetry optic sensor for medical device to India, Israel, Vietnam, US, New zealand, UK, France, Slovenia, Bulgaria, Italy, Poland 2011~.

Transmitted SpO2 oximetery optic sensor Qualified by Honeywell in Germany, start to supply 2011~

Shipped first SPO2 blood sensor for medical device to India and Argentina Sep 2011~

Shipped SPO2 blood sensor and module for medical device to Philippine Oct 2011~

Had exhibitions, Hochiminh Vietnam 3~5th Nov, and Daejeon Korea 16~18th Nov 2011.

Shipped DCM02 repeat order by wearable application in US Nov 2011

I Interviewed by KITA, on the International Trade Jan. 2012

Developed DCM03 to maximize lighting current 2012.

Have exhibition, APM in 9th WTA Hitech 22~24th May 2012

Supplied APM sensors to 37 countries by Feb 2013

Have exhibition with Taiwan agent, APM in Medicare Taiwan 2013

Tested and work with Texas Instrument, AFE4490 with DCM03 Mesurement Results Aug 27, 2013

Developed smallest DCM05 4.8x2.6x1.0mm for mobile devices 31 Dec 2013.

TI designed DCM03+AFE4403+MSP430 module for the wearable SpO2 devices June 2014, DCM03 Miniaturized Pulse Oximeter Design by TI

Mocacare developped a wearable device with DCM03 Jan 2015, www.mocacare.com

A sister company APMSensor was established 19 Aug 2016, supporting marketing and sales for APMKorea.

Developed smallest DCM06 DCM07 DCM08 DCM10 DCM06B DCM08B in a row for mobile devices ~Nov 2017.

DCM06 DCM07 DCM06B was developped and using for wrist artery BP application of Chronisense Israel.

APMKorea and APMSensor have moved office to new place, 52 Songnim-ro Daejeon Korea Nov 2016.

Developed DCM07T which is merged to check the body temperature, registered a Patent(10-1982576).

   

APM in Medicall Chennai2019 India, Booth 3C3 Hall3 25~28th July.

APM_KOTRA (Korea Trade-Investment Promotion Agency) office in Chennai India 2019~.

Developed DCM11F merged to check the body temperature, pressure and ECG for a watch type blood pressure wearable device, registrated 2nd patent 2022.

Supplying SpO2 oximetry optic sensors DDL2002M & DDN2092M for "COVID19 Home Care" by Korean government (KDCA) 2021~2022.

Developed 4wavelengths DDL2008M and Largest area 5x5mm PD DDN2094for Mindray China March 2022.

Developed DCM12, 3arrays in SWIR (1300, 1600nm) + compound PD May 2024.

Main Markets

China China

Germany Germany

India India

Saudi Arabia Saudi Arabia

U.S.A U.S.A

Main Product
Attached File

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more