Enerkeeper
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Category
- Electrical Equipment
Enertech Co., Ltd.
- Verified Certificate
-
16
Product name | Enerkeeper | Certification | - |
---|---|---|---|
Category | Electrical Equipment | Ingredients | - |
Keyword | energy keeper , energy-saving device , enerkeeper , power-saving device | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Applications
Enerkeeper a patented invention based on the state-of-the-art technology and incessant research efforts, which reduces the electricity consumption by around 15%. Enerkeeper-a power saving device can be setup for commercial, institutional and industrial usage.
During the use of electric equipments or appliances, the energy-wasting factors like ubalance, harmonics, and reactive power occur and lead to electric losses with rise in power consumption, low efficiency, and higher maintenance costs by shortening the lifespan of many electrical equipments.
Enerkeeper eliminates the energy-wasting factors, improves the quality of the power supply, and considerably reduces electrical bills, lengthening lifespan of the electrical equipments.
This innovative device is installed at the output of a transformer or a main circuit breaker. It works effectively and efficiently at any level of electrical load by improving power quality, reducing harmonics and phase current imbalance. Furthermore, this device yields good performance with just one unit whereas other compared products require a combination of two or more units. In fact, Enerkeeper is the only power-saving device that focuses on the majority of power quality problems for the total electrical load of small to large facilities.
Functions and Effects
Patented Technology
The EK ATW(Auto-Transformer Winding) technology helps in eliminating the unbalance, hamonics, and reactive power by offsetting the zero-phase current in each phase. As shown in the below in the diagram, the first coil is wound around the first and secone legs, and the third coil is wound around the third and first legs. In each phase, these coils should be wound in the opposite direction before connection to the neutral wire. This make out to keep constant magnetic-flux and opposite direction of the current flow in each phase and automatically reduces the distorted-wave-form currents, which are harmonice current and unbalance current.
Basically, an alternative current takes the form of sine wave, but as there is more increase in unbalance and harmonics, the basic sine wave form turns distorted, resulting an consumption to keep the constant output. The frequent occurrence of unbalance and harmonics results in an increase in current consumption, power consumption and highter resistance.
Enerkeeper is designed to eliminate the energy-wasting factors using the "zigzag" winding technology, increases the efficiency of electric equipments, and reduces the power consumption.
Harmonics
As electronic power controllers are used more, a rapid rise in nonlinear loads have been triggered, and the resulting harmonics has caused unexpeted electirc disturbances in the power supply systems.
Load types causing harmonics
|
Problems Arisin from Harmonics
|
|
|
Unbalance
Equipment Unbalance
According to the Article 115 of the Indoor wiring Regulation of the Korea Electric Association;
- 1-phase 3-wire type of low-voltage power -receiving units : 40% or less
- 3-phase 3-wire or 3-phase 4-wire type of low-/high-voltage power-receiving units : 30% or less
3-Phase Load Unbalance
According to the codes and standards of the US National Electrical Manufacturers' Association,
- A voltage unbalance of 3.0% results in approximately a 10% decrease in the capacity of the inductive motor; and
- A voltage unbalance of 4.4% leads to approximately a 20% decrease in the capacity of the inductive motor
Reactive Power
An increase in reactive power causes a reduction in transmission capacity compared to apparent power, resulting in a transmission loss. Accordingly, there is a naturally increasing loss in the electric generator or transformer. Then offset compensatons are generally taken as the action to improve power factor by using another reactive power of an opposite direction. The improvement of power factor provides many cost-effective advantages such as a reduction in electricity rates and a decrease in power consumption and transformer capacity.
Comparative Products
Product
|
Enerkeeper
|
Products controlling
Powr Factor |
Products controlling Frequency
|
|
Key Part
|
Enerkeeper
Auto transformer |
Prower capacitor
|
IC (control of voltage and frequency)
|
|
Main Functions
|
Compensation for harmonics and unbalance
|
Improvement of power factor
|
Power control and voltage adjustment
|
|
Product
|
Advantage
|
Available for all capacity levels
|
Moderate manufacturing and installation costs
|
Small size and light weight
|
Effective in different types of load combination
|
Effective in the place where no capacitor is installed
|
Minimized installation space
|
||
Minimized failure factors
|
Reduced basic rates due to power-factor improvement
|
Effective in the load of small-capacity lights
|
||
Disadvantages
|
Large size and heavy weight
|
Active power irreductible
|
Excessive voltage drop
|
|
Proper space required for installation
|
Less durable capacitor
|
Weak durability and poor resistance to moisture and vibration
|
||
Limited capacity supply
|
Frequent IC failure
|
|||
Structure and life span
|
Simple structure
|
Simple structure
|
Comparatively complicated in structure
|
|
Semi-permanent lifespan of 15~20 yrs.
|
Short lifespan of 3-8yrs.
|
Shor lifespan of 5-10 yrs.
|
||
Position / Quantity
|
Transformer or primary circuit breaker(secondary)
|
Transformer or primary circuit breaker(secondary)
|
Circuit breaker(secondary)
|
|
One unit of transformer capacity
|
Multi units(in case of excess of 1000 kVA)
|
Multi units by breaker capacity
|
||
Period of Investment Recovery
|
1.5 - 3.0 yrs.
|
2.5 - 5.0 yrs.
|
2.5 - 5.0 yrs.
|
Test Report
Economical Efficiency
CASE 1. Office Building
|
CASE 2. School Building
|
|
|
CASE 3. Chemical Plant
|
CASE 4. Foundry
|
|
|
Product Type
Indoor Type Products
EKS 1-phase
(Houses & Street lamps) |
EKS 3-phase
(Shops & Offices) |
EKL 3-phase
(Buildings & Industries) |
Outdoor Type Products
EKL 3-phase
|
EKO 3-phase
|
Product Components
Installation
- Use Enerkeeper for low-voltage parts of 600V or less.
- For installation, connect the system directly to the output part of a transformer or a main circuit breaker.
- Calculate the required capacity for installation based on the amount of loads and with reference to the transformer and circuit breaker.
Products List
Products
|
Capacity
(kVA) |
Current(A)
|
Size
|
Weight(kg)
|
||
Width
|
Height
|
Depth
|
||||
Three-Phase
|
30
|
43
|
420
|
500
|
550
|
60
|
50
|
72
|
520
|
550
|
650
|
110
|
|
75
|
108
|
520
|
750
|
700
|
160
|
|
100
|
144
|
200
|
||||
150
|
217
|
700
|
1000
|
850
|
230
|
|
200
|
289
|
300
|
||||
300
|
433
|
800
|
1800
|
1200
|
420
|
|
400
|
577
|
560
|
||||
500
|
722
|
800
|
2000
|
1400
|
760
|
|
600
|
866
|
780
|
||||
700
|
1010
|
900
|
2250
|
1500
|
910
|
|
800
|
1155
|
1040
|
||||
900
|
1299
|
1000
|
2350
|
1700
|
1170
|
|
1000
|
1443
|
1300
|
||||
1200
|
1732
|
1200
|
2350
|
1800
|
1600
|
|
1500
|
2165
|
1400
|
2350
|
2000
|
1950
|
|
1750
|
2526
|
2270
|
||||
2000
|
2887
|
1600
|
2550
|
2200
|
2600
|
|
2500
|
3609
|
3250
|
||||
3000
|
4330
|
3900
|
||||
Single-Phase
|
5
|
23
|
150
|
220
|
80
|
6
|
10
|
45
|
200
|
300
|
130
|
9
|
|
20
|
91
|
14
|
||||
30
|
136
|
260
|
370
|
140
|
21
|
|
40
|
182
|
500
|
750
|
700
|
70
|
|
50
|
227
|
80
|
||||
75
|
341
|
700
|
1000
|
850
|
112
|
|
100
|
455
|
140
|
1.Based on the 3 phase 400V & 1 phase 220V
2.Based on indoor conditions. Outdoor and EKO-type products are different.
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- PARK, HOON YANG
- Address
- #1506, 545, DunchonDaero,, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
- Product Category
- Electrical Equipment,Energy Saving Equipment & Parts
- Year Established
- 2003
- No. of Total Employees
- 1-50
- Company introduction
-
We are Enertech Co., Ltd. - a leader in the field of energy saving solutions.
Our best-known product, Enerkeeper Power Saver, Can reduce your electricity consumption by as much as 15%.Enertech devices are currently installed in the facilities of some of the largest corporations in the world, including Samsung and steel giant POSCO, as well as world-class hotels like the Grand Hyatt Dubai. Partners include Samsung C&T and Korea's state run power company, KEPCO.
Enertech Corporation was established in 2003 and holds 5 Republic of Korea and 3 international patents on devices including:
- Electricity Reduction
- Harmonic Frequency Reduction
- Apparatus of Hybrid Filter Type for Reduction of Harmonic frequency
- Apparatus for Harmonic Reduction, Distributed Saving Transformer
- Stand-by Power Saving Device
- Hybrid Power Saving TransformerEnertech prides itself on its commitment to satisfying its customers' needs and to truly understand each customer's technical issues. Our guiding principles of innovation, quality, safety and reliability are evident in our investment in engineering talent and quality manufacturing facilities.
- Main Markets
-
Australia
Chile
Philippines
Turkey
Viet Nam
- Main Product