Gastron Infrared Gas Detector GIR-3000
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- South Korea
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- infrared detector, gastron, gir-3000, ir gas detector
- Category
- Other Security & Protection Products
GASTRON CO.,LTD
- Verified Certificate
-
16
Product name | Gastron Infrared Gas Detector GIR-3000 | Certification | CE |
---|---|---|---|
Category | Other Security & Protection Products | Ingredients | - |
Keyword | infrared detector , gastron , gir-3000 , ir gas detector | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | South Korea | Stock | - |
Supply type | - | HS code | 9027100000 |
Product Information
Continuous detection of flammable, CO2, CO and N2O gases in explosion hazardous area with flameproof structure
State-of-the-art infrared detection principle
Long service lifetime(more than 5 years)
Operation in nonoxygen environment
Self-diagnosis function with built-in Microprocessor
Fast response time(<5 sec)
Built-in backlight LCD or OLED display
Auto calibration and program setting with a magnet bar
2-stage alarm, 1-trouble display and relay contact output
4-20mA (Current Source or Sink) output signal
Easy configuration of the monitoring system by RS-485 Modbus or HART communication
With the alarm unit, GTL-100 - Normal: Green LED - Alarm: Red LED, Buzzer(95dB) - Trouble: Yellow LED
Calibration and maintenance by one-man
Continuous detection of flammable, CO2, CO and N2O gases in explosion hazardous area with flame proof structure
State-of-the art infrared detection principle
Long service life time(more than 5 years)
Operation in non oxygen environment
Self diagnosis function with built-in Microprocessor
Fast response time(<5 sec)
Built-in back light LCD or OLED display
Auto calibration and program setting with a magnet bar
2-stage alarm, 1-trouble display and relay contact output
4-20mA (Current source or Sink) output signal
Easy configuration of monitoring system by RS-485 Modbus or HART communication
With the alarm unit, GTL-100 - Normal : Green LED - Alarm : Red LED, Buzzer(95dB) - Trouble : Yellow LED
Calibration and maintenance by one-man
*Measuring gas: Hydrocarbon gases (LNG, LPG, Methane, Buthane & etc) CO2 CO N2O
*Measuring type: Diffusion type
*Measuring method: Infrared type
*Measruing range: 0~100% LEL 0~9999ppm 0~100% Vol 0 - 5.0% Vol 0 - 2.0% Vol 0~4000ppm
*Sensor life time: Over 5 years
*Response time: <6sec / 90% scale, <3sec / 50% scale
*Accuracy: ±3% / Full scale
*Parameter control: Non intrusive control with a Magnet bar (calibration, maintenance, alarm setting)
*Operation mode display: 4-LED (Power, 2-stage alarm, 1-trouble)
*Measuring value display: LCD display (Built-in back light 2-Line, 16 characters) / OLED Type (Option)
*Alarm signal output: 2A@30VDC, 0.5A@125VAC (resistive load) / 3-SPST relay contact(2stage alarm, 1 trouble)
- Output signal -
Analog : Measuring signal : 4-20mA DC / Calibration signal : 3mA DC / Fault signal : 0mA DC /
Digital : RS-485 Modbus (Option) / 2mA (HART 7, HART Device Description Language available, Option)
*Material Housing : ALDC, SUS316(Option) / Sensor : SUS316
*Conduit connection: Standard : PF 3/4" Option : NPT 1/2", NPT3/4", M20 x 1.5P, M25 x 1.5P
*Mounting type: 2" Pole mount, Wall mount, Duct mount
*Operating temperature: -40℃ ~ +80℃
*Operating humidity: 5 ~ 99% RH (non-condensing)
*Dimensions: 156(W) x 323(H) x 110(D)mm
*Weight 3kg
KCs, ATEX, IECEx, NEPSI, UL, KR, MED, ABS, DNV, KC, KFI, CE, HART, SIL2, PESO, TRCU ex, IEC 60079-29-1:2008, CPA Approved
- Verified Certificate
-
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- CHAN YOUNG, SONG
- Address
- Gunpocheomdansaneop 1-ro,23, Gunpo-si, Gyeonggi-do, Korea
- Product Category
- Smoke Detector
- Year Established
- 1992
- No. of Total Employees
- 101-500
- Company introduction
-
Gastron Co. Ltd. has been doing its best only for technology development,
while thinking nothing but customers’ safety.
That was because of the characteristics of the products directly connected with precious life.
After ceaseless efforts, we have acquired various domestic and overseas certifications including
SIL2, HART, ATEX, IECEx, NEPSI, UL, etc. as well as 10 cases of patents related to gas detectors,
through which we have established ourselves firmly as an enterprise leading
domestic gas detector industry by obtaining trust.
Now, Gastron Co. Ltd. is in the process of taking a leap as an enterprise
taking responsibility for not only domestic safety but also the safety of industry fields
throughout the world. Through competition with overseas prestigious enterprises,
we intend to display the competence of domestic technology and provide safety for more people.
Our company’s gas detectors are already being supplied to Asia,
Southeast Asia, Mideast, etc. showing high satisfaction in relation to quality,
and hence brightening the prospect.
By the coming 2020, we will strive to become an enterprise providing gas safety
for the whole world by enlarging our market to Europe and Africa.
- Main Markets
-
China
India
Japan
Malaysia
Singapore
Taiwan
U.S.A
- Main Product