HCL-A1 Hydrogen Chloride Sensor (HCL Sensor)
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- U. Kingdom
- Brand name
- Alphasense
- Payment Terms
- Others,T/T
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- hydrogen chloride sensor, hcl sensor
- Category
- Sensors
Shenzhen ISweek Technology LTD
- Verified Certificate
-
8
Product name | HCL-A1 Hydrogen Chloride Sensor (HCL Sensor) | Certification | - |
---|---|---|---|
Category | Sensors | Ingredients | - |
Keyword | hydrogen chloride sensor , hcl sensor | Unit Size | - |
Brand name | Alphasense | Unit Weigh | - |
origin | U. Kingdom | Stock | - |
Supply type | - | HS code | - |
Product Information
HCL-A1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.
HCL-A1 Hydrogen Chloride Sensor HCL Sensor Schematic Diagram
HCL-A1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 25ppm HCl | 80 to 130 |
Response time | t90 (s) from zero to 25ppm HCl | < 300 |
Zero current | ppm equivalent in zero air | < ±2.5 |
Resolution | RMS noise (ppm equivalent) | < 1 |
Range | ppm HCl limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero, 40ppm HCl | 0 to 6 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
HCL-A1 Hydrogen Chloride Sensor HCL Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | nd |
Sensitivity drift | % change/year in lab air, monthly test | nd |
Operating life | months until 80% original signal (12 month warranted) | nd |
HCL-A1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL | ||
Sensitivity at -20°C | % (output at -20°C/output at 20°C) at 25ppm HCl | 65 to 90 |
Sensitivity at 50°C | % (output at 50°C/output at 20°C) at 25ppm HCl | 102 to 120 |
Zero at -20°C | ppm equivalent change from 20°C | < 0 to 4 |
Zero at 50°C | ppm equivalent change from 20°C | < +1 to -5 |
HCL-A1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY | ||
H2S sensitivity | % measured gas at ppm H2S | < 250 |
NO2 sensitivity | % measured gas at ppm NO2 | < -150 |
Cl2 sensitivity | % measured gas at ppm Cl2 | < -20 |
NO sensitivity | % measured gas at ppm NO | < 2 |
SO2 sensitivity | % measured gas at ppm SO2 | < 0.1 |
CO sensitivity | % measured gas at ppm CO | < 0.1 |
H2 sensitivity | % measured gas at ppm H2 | < 0.1 |
C2H4 sensitivity | % measured gas at ppm C2H4 | < 0.1 |
NH3 sensitivity | % measured gas at ppm NH3 | < 0.1 |
CO2 sensitivity | % measured gas at 5% CO2 | < 0.1 |
HCL-A1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS | ||
Temperature range | °C | -30 to +50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months at 3 to 20°C (stored in original container) | 6 |
Load resistor | Ω (recommended) | 10 to 33 |
Bias voltage | mV | not required |
Weight | g | < 6 |
Matched Transmitter board for HCL-A1 HCL Sensor
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Others,T/T | Shipping time | Negotiable |
- President
- Li xiaoyang
- Address
- 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan
- Product Category
- Sensors
- Year Established
- 2014
- No. of Total Employees
- 101-500
- Company introduction
-
<p>ISweek is the industry sourcing and direct marketing platform launched by OFweek, Chinese high-tech web portal.ISweek has gathered abundant high-quality industrial products around the world, and is dedicated to providing one-stop product distribution and procurement services for buyers, suppliers, traders, and manufacturers of industrial technology products.For the projects of telecom communications power, dynamic environmental monitor and access networks ring controllers, we provide fully imported sensing component solutions and support the manufacturers in the industry with necessary techniques and information.In industrial auto-control and building auto-control, we provide our customers with total solutions of sensingcomponents, control systems, general cabling and system integration.The gas sensor combined with the well-developed related temperature and humidity sensors can provide the increasing programs such as air purification, environment protection and granary monitor with excellent sensing and control component services.
- Main Product
Related Products
SMC Sensor
DH05 SERIES MICRO SWITCH
LOADCELL-CBSB (BEAM TYPE)
Ultrasonic Sensor for Underwater
Instantaneous Heating Module (IHM for Bidet)