PrimePell Infrared Gas Sensor for Oil Industry CH4 Sensor

PrimePell Infrared Gas Sensor for Oil Industry CH4 Sensor


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
U. Kingdom
Brand name
Clairair
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
infrared sensor, methane sensor, ch4 sensor, infrared gas sensor
Category
Sensors
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Shenzhen ISweek Technology LTD

Membership
BIZ
Country / Year Established
China China / 2014
Business type
Trading Company
Verified Certificate

8

Product name PrimePell Infrared Gas Sensor for Oil Industry CH4 Sensor Certification -
Category Sensors Ingredients -
Keyword infrared sensor , methane sensor , ch4 sensor , infrared gas sensor Unit Size -
Brand name Clairair Unit Weigh -
origin U. Kingdom Stock -
Supply type - HS code -

Product Information

 

PrimePell Pellistor Replacement Infrared Gas Sensor for Methane,Hydrocarbons

 

Features

• Operates independent of supply polarity, as a pellistor
• Pellistor mimic Bridge output
• Voltage rises across detector connections in gas, as a pellistor
• Relative responses to key hydrocarbons are similar to a pellistor
• Operating voltage range 3.0V - 5.0V
• Operating current 80mA typical
• Latest technology MEMS detectors
• Sensing ranges: 0-100% LEL Methane, 0-100% LEL Hydrocarbons or 0-100% Volume Methane
• All metal construction with isolated housing
• Small internal volume
• Flexible electronic configuration access
• User calibration also enabled by hardware connections
• Wide operating temperature range
• Fast response
• Immunity from ‘poisoning’

 

Description and Operation

The PrimePell sensor uses the non-dispersive infrared method to detect the presence of hydrocarbon gases. The sensor contains an infrared radiation source, a dual element custom infrared detector, a unique optical waveguide into which gas diffuses and internal ARM7 core microprocessor based electronics to provide a voltage output which is independent of the power supply polarity. The sensors can be configured to provide a pellistor format output, typically mid supply at zero with the voltage output increasing with respect to the detector pin by 100mV at range, or a linear voltage output, typically 0.4V – 2.0V over range with respect to the negative supply pin. Inaddition, the output can be read and the internal configuration can be accessed by a serial communications link.The communication link contacts are pads in the 3 pin version PrimePell and pins in the 5 pin version PrimePell.The internal electronics perform all the functions of driving the optical parts of the sensor, extracting the detectorsignals, converting the signals to a concentration, applying temperature compensation and scaling the output.When in a pellistor configuration, the PrimePell can replace catalytic sensors in existing circuitry subject to thepower supply  requirements.  External components will be required to meet the power supply requirement when a PrimePell is used in constant current pellistor circuitry. The PrimePell is not currently Ex approved so should behoused in a suitable Ex enclosure when used in Hazardous areas.

 

Hydrocarbon Response Characteristics

Unless otherwise specified, the PrimePell is calibrated to provide an output signal linearised for %LEL methaneduring manufacture. The LEL is equivalent to 4.4% volume methane or 5% volume methane depending on thegeographic requirement and must be specified when ordering. The PrimePell can also be calibrated to 0-100%volume methane or 0-100%LEL of a particular hydrocarbon if required. Note that the PrimePell will respond to arange of hydrocarbon gases irrespective of the calibration. Note that, unlike a pellistor, a PrimePell will not detect acetylene or hydrogen. A Prime4 sensor is available that will selectively detect acetylene. 

 

Temperature Compensation

The PrimePell is temperature compensated for both zero and span at the calibration gas concentration level.

 

Sensor Warmup

When power is first applied or when a reset has occurred or during recovery from a fault condition the PrimePelloutputs –1.56% of scale (0.375V in voltage mode or –1.56mV in pellistor mode) for 5 seconds then outputs 0% of scale for a warmup period (default is 15 seconds). After this time the output follows the extracted gas value.

 

Fault Indication

The PrimePell continuously monitors several internal parameters to ensure that the internal hardware andsoftware are operating correctly. If a fault condition is detected then the output is set to 0V in the case of a voltage output (equivalent to –25% FSD for a 4mA zero) or to approximately –200% scale in pellistor output, emulating a partly open compensator. Some faults are recoverable (e.g. a brown-out in incoming supply voltage) and the PrimePell continuously checks for possible recovery. If a fault can be recovered from then the output follows the sensor warmup sequence before following the extracted gas value.

 

Failure Modes Effects and Diagnostic Analysis (FMEDA)
An FMEDA on the PrimePell produced the following summary results:
Conditions: Ground Fixed, JAN to MILHDBK217F
Subsystem type = B (Complex using microcontrollers or programmable logic),
Hardware Fault Tolerance = 0,
High Demand (Continuous Use of Operation):
λSD= 921 FIT,λSU= 3 FIT,λDD= 859 FIT,λDU= 96 FIT, SFF = 94.9%,
Probability of Dangerous Failure per Hour = 9.5 x 10-7

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Shenzhen ISweek Technology LTD

Country / Year Established
China China / 2014
Membership
BIZ
Business type
Trading Company

8

President
Li xiaoyang
Address
16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan
Product Category
Sensors
Year Established
2014
No. of Total Employees
101-500
Company introduction
<p> 

ISweek is the industry sourcing and direct marketing platform launched by OFweek, Chinese high-tech web portal. 

ISweek has gathered abundant high-quality industrial products around the world, and is dedicated to providing one-stop product distribution and procurement services for buyers, suppliers, traders, and manufacturers of industrial technology products.

For the projects of telecom communications power, dynamic environmental monitor and access networks ring controllers, we provide fully imported sensing component solutions and support the manufacturers in the industry with necessary techniques and information.

In industrial auto-control and building auto-control, we provide our customers with total solutions of sensing 
components, control systems, general cabling and system integration.

The gas sensor combined with the well-developed related temperature and humidity sensors can provide the increasing programs such as air purification, environment protection and granary monitor with excellent sensing and control component services.

 

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more