Specifications
| Size | - | Weight | - | Stock | - |
|---|---|---|---|---|---|
| Country of Origin | China | ||||
| Production method | Negotiable | ||||
Trade Terms
| Payment Terms | T/T | ||||
|---|---|---|---|---|---|
| Price(FOB) | Negotiable | MOQ | Negotiable | ||
| Transportation | - | ||||
| Lead time | Negotiable | Shipping time | Negotiable | ||
Company
-
Country / Year Established
-
Membership
- BIZ
Business typeDistributor
-
Verified Certificate
-
9
-
9
-
Main Export Markets
-
Austria
-
Canada
-
USA
-
Product Description
Specification
P6300 handheld power qualityanalyzer, support to measure the power frequency system of 50Hz/60Hz powergrid, it can record all power quality parameters including of harmonic,voltage, current, frequency, fluctuation, flicker, power and 3-phase imbalance,etc. The 6300 possesses high class power quality measurement function,meanwhile it provides professional host computer analyze software to processsecondary analysis, and provides user the most accurate power fault diagnosisanalysis.
| General Parameter | ||
| Parameter | Parameter type | Description |
| Environment | working environment | temperature 0℃~+45℃,humidity <90rh% |
| memory environment | temperature -20℃+50℃,humidity <95rh% (noncondensing) | |
| Memory | type | TF card |
| capacity | 8G | |
| Power supply | adapter input | 110V-240V,50Hz |
| adapter output | 15V,3A | |
| Battery | type | chargeable polymer li-ion battery,5000mAh |
| battery working time | ≥5h | |
| battery charge time | minimum 5h(environment temperature 25℃) | |
| power saving function | LCD backlight brightness adjustable, standby time adjustable | |
| Display | size | 112.8×84.6mm |
| color | 260k color | |
| resolution | 640×480 | |
| brightness | max 350 cd/m²(Typ.),adjustable | |
| contrast | 500:1(Typ) | |
| visual angle | 70/70/50/70 (Typ.)(CR ≥ 10) (left/right/up/down) | |
| Security | meet standard | GB 4793.1-2007/IEC 61010-1:2001, CATIII 1000V/CATIV 600V |
| banana input end | CATIII 1000V/CATIV 600V | |
| Crosstalk | among voltage input end | under nominal frequency -60dB |
| voltage and current input end | under nominal frequency -95dB | |
| Common-mode rejection | CMRR | >60dB |
| Measure standard | measure method | IEC 61000-4-30 |
| measure feature | IEC 61000-4-30 class A | |
| flicker | IEC 61000-4-15 | |
| harmonic | IEC 61000-4-7 | |
| power decompoistion | IEEE 1459 | |
| Electromagnetic compatibility | standard | class 4:GB/T 17626.2-2006 electrostatic discharge immunity |
| class 3:GB/T 17626.3-2006 RFEMS (radio-frequency electromagnetic field radiated immunity) | ||
| class 3:GB/T 17626.4-2008 Electrical fast transient burst immunity | ||
| class 3:GB/T 17626.5-2008 Surge (impact) immunity | ||
| class 3:GB/T 17626.8-2006 PFMF (Power Frequency Magnetic Field Immunity) | ||
| class 3:GB/T 17626.9-1998 Pulse Magnetic Field Immunity | ||
| class 3:GB/T 17626.12-1998 Oscillatory waves immunity | ||
| Environment reliability | standard | GB/T 2423.1-2008 low temperature |
| GB/T 2423.2-2008 high temperature | ||
| GB/T 2423.4-2008 Alternating hot and humid | ||
| GB/T 2423.5-1995 impact | ||
| GB/T 2423.10-2008 shake | ||
| GB/T 2423.22-2002 temperature variation | ||
| Measure parameter | ||
| Function | Parameter type | Description |
| Recorder | oscilloscope | A、B、C、N Each phase voltage and current waveform in real time |
| voltage current frequency | frequency value, voltage effective value, voltage semi-wave effective value, voltage positive peak, voltage negative peak, voltage waveform factor, current effective value, current semi-wave effective value, current positive peak, current negative value, current waveform factor | |
| power and electric energy | active power, reactive power, apparent power, power factor, displacement power actor, active electric energy, reactive electric energy, apparent power electric energy | |
| voltage harmonic | THD、DC、1-50times harmonic、0-49times inter-harmonics、1-35times ultraharmonics | |
| current harmonic | THD、DC、KF、1-50times harmonic、0-49times inter-harmonics、1-35times ultraharmonics | |
| harmonic power | THD、DC、1-50times harmonic power | |
| flickering | PST(short flicker)、PLT(long flicker) | |
| imbalance | positive sequence voltage and current, negative sequence voltage and current, zero sequence voltage and current, unbalance degree | |
| energy consumption | active, reactive, apparent power decomposition, line loss power, line loss charge, pollution assess | |
| demand | demand | |
| event record | voltage swell and sag, voltage interruption, stroke current,short flicker out-of-limit, long flicker out-of-limit,voltage up out-of-limit, voltage down out-of-limit, frequency up out-of-limit, frequency down out-of-limit,,steady-state voltage fluctuation, voltage imbalance out-of-limit, voltage THD out-of-limit, voltage 1-50 times harmonic out-of-limit, current 2-50 times harmonic out-of-limit | |
| Inverter | DC | DC voltage, DC current, DC power, ripple voltage, ripple voltage containing rate |
| AC | frequency, voltage effective value, current effective value, total apparent power, total active power, total power factor, fundamental power, fundamental power factor | |
| efficiency | conversion efficiency | |
| Transient | voltage | voltage effective value, voltage semi-wave effective value, voltage positive peak, voltage negative peak |
| current harmonic | current effective value, current semi-wave effective value, current positive peak, current negative peak | |
| frequency | frequency | |
| event record | voltage swell, voltage dip, voltage interruption | |
| Monitor | Monitor | voltage effective value, 1-50times voltage harmonic, PLT, voltage dip, voltage swell, voltage interruption, steady-state voltage fluctuation, voltage imbalance degree |
| Parameter accuracy | ||
| Parameter | Parameter type | Description |
| Frequency | nominal frequency | 50Hz/60Hz |
| measure method | operation by 10/12 circle | |
| resolution | 0.001Hz | |
| measure width | 42.5Hz - 69Hz | |
| measure accuracy | ±0.001Hz | |
| Voltage effective value | measure method | operation by 10/12 circle square root value |
| resolution | 0.001V | |
| measure range | 1V - 1000V | |
| measure accuracy | 0.1% of nominal voltage | |
| Current effective value | measure method | operation by 10/12 circle square root value |
| resolution | 0.001A | |
| measure range | different range by different transformer | |
| measure accuracy | 0.1%+CT accuracy | |
| Power | measure method | active power: square of 10 circle wave voltage current Instantaneous value |
| apparent power: 10 circle voltage effective value multiply current effective value | ||
| reactive power: square of apparent power minus square root of active power | ||
| power factor: active power ratio apparent power | ||
| resolution | 0.001W | |
| measure range | due to voltage measure range and current transformer measure range | |
| measure accuracy | 0.5%+CT accuracy | |
| Voltage/Current harmonic | measure method | conform to IEC61000-4-7, analyze window range 10 circle |
| measure type | effective value, containing radio, phase angle | |
| times/frequency | 50times /50Hz-2500Hz | |
| measure accuracy | voltage harmonic >1% nominal value:deviation < 1% indication | |
| voltage harmonic < 1% nominal value:deviation < 0.05% nominal voltage value | ||
| current harmonic >3% nominal value:deviation < 1% indication+CT accuracy | ||
| current harmonic < 3% nominal value:deviation < 0.05% current measure range+CT accuracy | ||
| Voltage/Current inter-harmonic | measure method | conform to IEC61000-4-7, analyze window range 10 circle |
| measure type | effective value, containing radio, phase angle | |
| times/frequency | 50times /25Hz-2475Hz | |
| measure accuracy | voltage harmonic >1% nominal value:deviation < 1% indication | |
| voltage harmonic < 1% nominal value:deviation < 0.05% nominal voltage value | ||
| current harmonic >3% nominal value:deviation < 1% indication+CT accuracy | ||
| current harmonic < 3% nominal value:deviation < 0.05% current measure range+CT accuracy | ||
| Harmonic power | measure method | conform to IEC61000-4-7, analyze window range 10 circle |
| measure type | effective value, containing radio, phase angle | |
| times/frequency | 50times /50Hz-2500Hz | |
| measure accuracy | voltage current harmonic >1% nominal value:deviation < 1% indication+CT accuracy | |
| voltage current harmonic < 1% nominal value:deviation < 0.05% nominal value +CT accuracy | ||
| Voltage/Current ultraharmonic | measure method | conform to IEC61000-4-7, analyze window range 10 circle |
| measure type | effective value, containing radio, phase angle | |
| times/frequency | 35times /2100Hz-8900Hz | |
| measure accuracy | voltage harmonic >1% nominal value:deviation < 1% indication | |
| voltage harmonic < 1% nominal value:deviation < 0.05% nominal voltage value | ||
| current harmonic >3% nominal value:deviation < 1% indication+CT accuracy | ||
| current harmonic < 3% nominal value:deviation < 0.05% current measure range+CT accuracy | ||
| Imbalance degree | measure method | voltage negative sequence imbalance degree: negative sequence voltage ratio positive sequence voltage |
| voltage zero sequence imbalance degree: zero sequence voltage ratio positive sequence voltage | ||
| current negative sequence imbalance degree: negative sequence current ratio positive sequence current | ||
| current zero sequence imbalance degree: zero sequence current ratio positive sequence current | ||
| resolution | 0.001% | |
| measure accuracy | voltage imbalance degree: ±0.2% | |
| current imbalance degree: ±0.5% | ||
| Flicker | measure item | short flicker(PST), long flicker(PLT) |
| measure method | according to IEC61000-4-15 operate PST(10 mins)PLT(2 hours) | |
| measure range | 0 - 20 | |
| measure accuracy | ±5% | |