32AGS -Auto recovery Earth Leakage Circuit Breaker
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Brand name
- Kum Sung Electric
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- circuit breaker, auto recovery earth leakage circuit breaker, automatic recovery, time invariant type
- Category
- Electronic Products , Active Components , Wall Switches , Other Switches
KumSung Electric Co.,Ltd.
- Verified Certificate
-
11
Product name | 32AGS -Auto recovery Earth Leakage Circuit Breaker | Certification | - |
---|---|---|---|
Category |
Electronic Products
Active Components Wall Switches Other Switches |
Ingredients | - |
Keyword | circuit breaker , auto recovery earth leakage circuit breaker , automatic recovery , time invariant type | Unit Size | - |
Brand name | Kum Sung Electric | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
32AGS (Auto recovery Earth Leakage Circuit Breaker)
The Automatic recovery Earth Leakage Circuit Breaker has an intelligent automatic recovery scheme. The automatic recovery scheme employs monitoring load side actual leakage current in real time through a detection circuit and determining the abnormality and the breakage reasons on braking to execute the automatic recovery, not a scheme of the time invariant type or a voltage application type using a battery.
Features
01.Turn off automatically after a short circuit at short return trip
- Only when the load short-circuit protection earth (ground) voltage through the "short-circuit monitoring removal"
Leakage Trip does not put the load side to actual load The self-reversal leakage current off automatically after a short recovery To perform cutting-edge technology to develop All existing auto repair and complete the circuit breaker differentiation Declaration.
November 2008 revised safety standards for Technology and Standards
- Patent - No. 10-0782300 Korea (earth leakage protection only when the load current -(leakage current) to detect short-circuit protection device
- International Patent -PCT/KR2008/00057 (Blocker The only source of patent pending)
02.Automatically return to the circuit breaker - in the existing structure of reality
- Breakers to minimize structural changes and the appearance of the Standardized(Domestic auto repair miniature circuit breaker)
In general the structure of the circuit breaker be used with minimal changes in With the addition of auto repair equipment operation and safety of the product increases the reliability of
- Patent - No. 10-0718530 Korea(short-circuit protection device equipped with means for automatic return)
- International Patent -PCT/KR2007/001967
03.Grounding and Surge / circuit protection devices, integrated
-
Grounding
Attachment Ground Transportation functions. -
Surge / circuit protection devices, integrated
Associated with ground at the bottom built-in safeguards to
Existing leakage circuit breaker and the surge could not be functioning
Added protection, cause a simple impulse noise and light malfunction minimize blocking
Surge (15KVA) to withstand the internal design.
04.Operating display
- green light - normal operation
- flashing green - manual block
- red light - short-circuit
05.Safety improvements
- Internal fuse (fuse built-in semi-permanent)
Add to the fuse circuits, circuits ensure reliability. - blocking terminal zero volts (0 V) realized
Automatic recovery of the circuit breaker was a common phenomenon after blocking load side Fine resolution voltage-sensing phenomena, load side secure safety
06.Auto / manual selection
07.Products liability insurance
- Hanwha Non-Life Insurance
300 million won compensation limit (No.20081862051000)
32 AGS Specification
|
||||
Basic Specifications |
Acquired standard |
EK certificate
|
obtained June 12, 2009 |
|
Rated Current (A) |
15/20/30 |
|||
Number of poles and elements |
2P 2E |
|||
Number of usable phase wire |
1ø2W |
|||
Protecting function |
Lightning/Overload/Short circuit/Electric shock/mpulse non-tripping |
|||
Rated voltage(V AC) |
110/220 |
|||
Rated sensitive current |
30mA |
|||
Rated non-tripping current |
15mA |
|||
Operating time(sec) |
Within 0.03sec |
|||
Earth leakage tripping scheme |
Electronic type, current operating type |
|||
Product size |
W*H*D = 40*84*70(mm) |
|||
Rated breaking capacity |
2.5KA |
|||
Special Specifications |
Leakage detecting device |
Detection of leakage relieve |
Patent registration/PCT application |
|
Automatic recovery device |
When Breaking by lightning, noise, etc. – Automatic recovery |
Patent registration/PCT application |
||
When Breaking by leakage - Automatic recovery after leakage |
||||
When Breaking by short circuit and overload – No recovery |
||||
Breaking reason display |
Automatic
|
Green LED lighting |
||
Passive
|
Green LED flickering |
|||
Leakage
|
Red LED flickering |
|||
Circuit portection/protection from lightning |
Built-in fuse and surge circuit |
Maximum : 10kA |
||
Ground terminals |
removable terminal |
|||
Channel attached |
Teaser improve joint working |
Field Applications - panel of street lights
Field Applications - traffic signal controller
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Han Sik Lee
- Address
- #416, 272, Digital-ro, Guro-gu, Seoul
- Product Category
- Active Components,Other Switches
- No. of Total Employees
- 1-50
- Company introduction
-
2012.01
Acquired ISO 14001 Certificates for Environmental Management System.2011.12
Registered as an Eco-Partner of Samsung SNS.2011.11
Patent registration (No. 10-1072976): earth leakage circuit breaker immediately blocking high currents.2011.09
Appointed as a Promising SME in Kyeonggi-do.2011.07
Joint patent application with the Korea Electrical Engineering and Science
Research Institute: “DC Leakage Circuit Breaker”.2011.06
Joint patent with the Seoul Metropolitan Facilities Management Corporation (SMFMC): “Local Government Integrated Communication Networks and the Panel Board”.2011.06
Patent registration (No. 10-1042988): power-saving electromagnetic switch.2011.05
The Research subject on creating the foundation for the product safety technology was selected (worth of 150 million KRW).1994.01
Began broadcasting/communication business.1992.02
Began power distribution business.1991.03
Began automation business.1990.09
Established Kumsung Mechatronics (금성기전사) and began electric outfitting business
- Factory Information
-
KumSung Electric Co.,Ltd.
- Main Product
Related Products
Cafe Specialty A1_SELF-SERVE HOT & ICED CAFE MACHINE with various cashless payment system
IOT Smart Digital Door Lock Epic ES-F500D
Lukas Dash cam LK-9750 Duo
Sink dryer
DuoPASS