Patient Monitor
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Brand name
- Jumper
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Category
- Multi-Parameter Monitor
Shenzhen Jumper Medical Equipment Co., Ltd
- Country / Year Established
- China /
- Business type
- Others
- Verified Certificate
-
12
Product name | Patient Monitor | Certification | - |
---|---|---|---|
Category | Multi-Parameter Monitor | Ingredients | - |
Keyword | patient monitor , dignosis equipment , healthcare equipment , medial equipment | Unit Size | - |
Brand name | Jumper | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
15 inch patient monitor
JPD-800B (15’’)
Specification
² 15 inch TFT; Resolution: 1024*768
² ECG , Spo2 , PR , NIBP , RR , Temp
² Operating condition
Working Storage
Temperature 0–40℃ -20-70℃
Humidity 15-95% 10- 90%
² Power supply
External power requirement: AC 100-250V 50/60hZ
² Classification
Anti-electroshock type Class I equipment
Anti-electroshock degree CF defibrillation;
² Accordant Standard
GB9706.1:1995
GB/T14710:1993
YY0089:1992
YY91079:1999
Parameter
ECG
Leads Mode; 5 leads; Ⅰ、Ⅱ、Ⅲ、Avr、Avl、Avf、V
Gain(mm/mV): 1/4,1/2,1,2,4
Scanning speed; 12.5mm/s、25mm/s、50mm/s
Frequency response: Diagnosis 0.05-130Hz
Monitoring 0.5 – 40Hz
Operation 1.0- 20Hz
Heart rate range: 15-350 BPM
Heart rate accuracy:±1%
ST segment analysis:-0.8-+0.8Mv
ST segment accuracy:±0.02Mv
NIBP
Measure and Alarm Range
Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 220 mmHg
MEAN 20 ~ 240 mmHg
Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN 20 ~ 170 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Static pressure range: 0~300mmHg
Static pressure accuracy: ±3mmHg or 2%
Resolution: 1mmHg
Protection mode; dual over voltage protection
SPO2
Measure range: 1-100%
Accuracy: ±2% (70-100%)
Resolution: 1%
Pulse rate
Measure range: 20-300 BPM
Accuracy: ±2 BPM
Resolution: 1 BPM
Temperature
Channel; 2
Measure range: 0-50 ℃
Accuracy: ±0.1 ℃
Resolution: 0.1 ℃
Respiration
Measure range: Adult 0~120BrPM
Pediatric/ Neonatal 0~150BrPM
Accuracy: ± 2%
Resolution: 1 BPM
IBP(optional)
Accuracy (no sensor); ±2%or1mmHg
Band width: Normal mode: DC~40Hz
Smooth mode: DC~12.5Hz
ETCO2
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy: ±2 mmHg < 5.0% CO2 (at ATPS)
Respiration: 3 – 150 bpm
Depth of anesthesia (optional)
EEG sensitivity ±400μV
Noise <2μVp-p , <0.4μV RMS,1-250Hz
CMRR >100Db
Input impedance >50Mohm
Sample rate 2000 samples/sec.(14 bits equivalent)
CSI and update 0-100.Filter 6-42Hz,1 sec.update
EMG 0-100logarithmic.Filter75-85Hz,1sec.update
BS% 0-100%.filter 2-42 Hz,1 sec.update
Function
* 6 display interface
* 720 hours trend data storage, 12 hours waveform review
* voice alarm
* support wired and wireless networking
* support software upgrade online
* ST segment can be adjusted
* support nurse call system
Option
Lead-acid battery (external plug)
Recorder (built-in)
IBP
ETCO2
Monitor depth of anesthesia
Anesthesia gas monitoring
Oxygen monitoring
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Mr. Fu
- Address
- 5th Floor, Building No. 34, Baoyuan Industrial Zone, Xixiang street, Bao’an Dis., Shenzhen, China P.O. 518102
- Product Category
- Blood Pressure Monitor,Multi-Parameter Monitor,Oximeter
- No. of Total Employees
- 51-100
- Company introduction
-
Shenzhen Jumper, China. is a medical equipment manufacturer who specializes in obstetrics and gynecology monitoring for more than 13years.
The main products are Fetal Doppler (both home use and hospital use), Fetal Monitor, Blood Pressure Meter, Thermometer, and Patient Monitors and so on.
Our bestseller AngelSounds Fetal Doppler gets a high reputation in International market, especially in Europe and UK.
Jumper is also a CE, FDA approved company. Now looking for agents worldwide.
- Main Markets
-
Brazil
Canada
Indonesia
Israel
South Korea
Taiwan
U.S.A
- Factory Information
-
- Main Product
Related Products
Getein 1100 Immunofluorescence Analyzer
Patient Monitor, VP-1200
Patient Monitor VP-1000
Multi-parameter Patient Monitor
Urine Analysis Test Strip Self-Stik Series