Patient Monitor VITAPIA 7000K
Negotiable Min Order Quantity Unit
- Required Quantity
-
- Place of Origin
- Payment Terms
- Negotiable
- Production method
- Negotiable
- Shipping / Lead Time
- Negotiable / Negotiable
- Keyword
- Category
- Other Health Care Products
Trismed Co., Ltd.
- Verified Certificate
-
16
Product name | Patient Monitor VITAPIA 7000K | Certification | - |
---|---|---|---|
Category | Other Health Care Products | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Multi Parrameter Patient Monitor
VITAPIA 7000K
- 12.1" High brightness TFT LCD display
- Portable, streamline handle design
- Big figure display
- ECG Waveforms of 7-lead displayed in one screen
- 480-hour tabular and graphic trends and data storage
- Compatible and self identify 3-lead and 5-lead ECG cable
- NIBP dual Over pressure protection
- Isolated floating, anti defibrillation protected and anti high-frequency interference
- Networking capacity standard parameter and configuration
- 3/5 lead ECG, RESP, SPO2, NIBP,TEMP
- Optional parameter & configuration
- 2-IBP, 2-TEMP, recorder, 12-lead ECG, ETCO2, Network
Multi Parameter Patient Monitor VITAPIA7000K Technical Specifications
Classification | ||
Anti-electroshock type
|
class I equipment and internal powered equipment | |
EMC type
|
Class A | |
Anti-electroshock degree
|
ECG(RESP), SPO2, NIBP, IBP, TEMP, CFCO2 | |
Specifications | ||
Size Monitor
|
310 x 140 x 263mm(Type 7012K) | |
Weight Monitor
|
3.8kg | |
Temperature
|
Working 5~40°C Transport and Storage -20~60°C |
|
Humidity
|
Working <80% Transport and Storage < 80%(no coagulate) |
|
Altitude
|
Working -500 to 4,600m Transport and Storage -500 to 13,100m |
|
Power Supply
|
100/240VAC, 50/60Hz, Pmax=150VA, FUSE T 1.6A(Type 7012K) 9VDC, Pmax=36VA(Type 7000H) |
|
Display | ||
Device
|
12.1" in Color TFT \, 3LED | |
Messages
|
8 Waveforms Maximum 1 Alarm LED(Yellow/Red) 1 Power LED(Green) 1 Battery Charge LED(Yellow) 3 Sound Mode corresponding Alarm Mode |
|
Signal Interface | ||
External Display
|
Standard VGA | |
ECG Output
|
BNC | |
Amplitude
|
1mV | |
Accuracy
|
<5% | |
Impedance
|
50ohm | |
Signal Delay
|
<20ms | |
Battery | ||
Battery
|
Rechargeable 3.7A/Hr 7.4V Li battery Operating time under the normal use and full charge greater than 120min Operating time after the first alarm of low battery will be about 5min |
|
Recorder(Option) | ||
Record Width
|
48mm | |
Paper Speed
|
25/50mm/s | |
Trace
|
2 | |
Recall | ||
Trend
Recall |
Short
|
1hrs, 1Second Resolution |
Long
|
72hrs. 1Min. Resolution | |
Alarm Event Recall
|
400 NIBP measurement data | |
ECG | ||
Lead Mode
|
5 Leads(R, L, F, C or RA, LA, LL, RL, V) | |
Lead Selection
|
I, II, III, avR, avL, avF, V | |
Waveform
|
2ch | |
Lead Mode
|
3 Leads(R, L, F or RA, LA, LL) | |
Lead Selection
|
I, II, III | |
Waveform
|
1ch | |
Gain
|
x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV | |
HR and Alarm Range
|
Adult
|
15~300bpm |
NEO/Ped
|
15~350bpm | |
Accuracy
|
±1% or ±1bpm, which great | |
Resolution
|
1bpm | |
Sensitivity
|
>200uVP-P | |
Differential Input Impedance
|
>5Mohm | |
CMRR
|
Monitor>105dB Operation>105dB Diagnosis>85dB |
|
Electrode offset potential
|
±300mV | |
Leakage Current
|
<10uA | |
Baseline Recovery
|
<3s After Defi. | |
ECG Signal Range
|
±8mV(Vp-p) | |
Bandwidth
|
1~20Hz(+0.4dB, -3dB) 0.5hz~40Hz(+0.4dB, -3dB) 0.05Hz~75Hz(+0.4dB, -3dB), 76Hz~150Hz(+0.4dB, -4.5dB) |
|
Calibration Signal
|
1mV(Vp-p), ±5% Accuracy | |
ST Segment Monitoring Range
Measure and Alarm |
-2.0~+2.0mV | |
ARR Detection
|
Type
|
ASYSOLE< VFIBNTAC, COUPLET, BIGMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Alarm
|
Available | |
Review
|
Available | |
RESPARATION | ||
Method
|
Impedance between R-F(RA-LL) | |
Differential Input Impedance
|
>2.0Mohm | |
Measuring Impedance Range
|
0.3~5.0Ohm | |
Base line Impedance Range
|
0.1~2.5kOhm | |
Badwidth
|
0.3~2.5Hz | |
Resp. Rate
|
Adult 0~120rpm | |
Measuring and Alarm Range
|
Neo/Ped 0~150rpm Resolution 1rpm Accuracy ±2rpm Apean Alarm 10~40 |
|
NIBP | ||
Method
|
Oscillometric | |
Mode
|
Manual, Auto, STAT | |
Measuring Interval in AUTO Mode
|
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480, 760Min. | |
Measuring Period in STAT Mode
|
5 Min. | |
Pulse Rate Range
|
40~240bpm | |
Alarm Type
|
SYS, DIA, MEAN | |
Measuring and alarm Range
|
||
Adult Mode
|
SYS
|
40~270mmHg |
DIA
|
10~215mmHg | |
MEAN
|
20~235mmHg | |
Pediatric Mode
|
SYS
|
40~200mmHg |
DIA
|
10~150mmHg | |
MEAN
|
20~165mmHg | |
Neonatal Mode
|
SYS
|
40~135mmHg |
DIA
|
10~100mmHg | |
MEAN
|
20~110mmHg | |
Resolution
|
Pressure
|
1mmHg |
Accuracy Pressure
|
||
Maximum Mean error
|
±5mmHg | |
Maximum Standard deviation
|
±8mmHg | |
Overpressure
Protection |
Adult
|
297±3mmHg |
Pediatric
|
240±3mmHg | |
Neonatal
|
147±3mmHg | |
SpO2 | ||
Measuring Range
|
0~100% | |
Alarm Range
|
0~100% | |
Resolution
|
70%~100%±2% 0%~69% unspecified |
|
Actualization interval
|
about 1sec. | |
Alarm Delay
|
10 sec. | |
Pulse Rate Measuring and Alarm Range
|
0~250bpm | |
Resolution
|
1bpm | |
Accuracy
|
±2bpm | |
TEMPERATURE | ||
Channel
|
2 | |
Measuring and Alarm Range
|
0~50°C | |
Resolution
|
0.1°C | |
Accuracy
|
±0.1°C | |
Actualization interval
|
about 1sec. | |
Average Time Constant
|
<10 sec. | |
IBP(Option) | ||
Channel
|
2 | |
Label
|
ART, PA, 0000CVP, RAP, LAP, ICP, P1, P2 | |
Measuring and
Alarm Range |
ART
|
-50~350mmHg |
PA
|
-6~120mmHg | |
CVP/RAP/
LAP/ICP |
-10~40mmHg | |
P1/P2
|
-10~300mmHg | |
Press Sensor
|
Sensitivity
|
5uV/V/mmHg |
Impedance
|
300~3000Ohm | |
Resolution
|
1mmHg | |
Accuracy
|
±2% or 1mmHg which great | |
Actualization interval
|
about 1sec. | |
CO2(Option) | ||
Methos
|
Infra-red Absorption Technique | |
Measuring Mode
|
Sidestream or Mainstream(option) | |
Side-stream mode sampling gas flow rate
|
50ml/Min(option) | |
Measuring
Range |
CO2
|
0~150mmHg |
INSCO2
|
0~150mmHg | |
AwRR
|
0~150rpm | |
Resolution
|
CO2
|
0.1mmHg(0~69mmHg), 0.25mmHg(70~150mmHg) |
INSCO2
|
0.1mmHg(0~69mmHg), 0.25mmHg(70~150mmHg) | |
Accuracy
|
CO2
|
±2mmHg, 0~40mmHg ±5% of reading, 71~100mmHg ±8% of reading, 71~100mmHg ±10% of reading, 101~150mmHg |
AwRR
|
±1rpm | |
Initialization Time | ||
Mainstream
|
Capnogram displayed in less than 15sec at an ambient temp. of 25°C, full specifications within 2min. | |
Sidestream
|
Capnogram displayed in less than 20sec at an ambient temp. of 25°C, full specifications within 2min. | |
Mainstream Rise Time:
|
Less then 60ms-Adult Reusable or Single-Patient-Use Airway Adapter | |
Sidestream Delay Time
|
2~3 Sec. | |
Alarm Range
|
CO2 0~150mmHg INSCO2 0~150mmHg AwRR 2~150bpm |
|
Suffocation Alarm Delay
|
AwRR 10~60sec. |
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- Hoon-Kyu Lee
- Address
- 409 SMECA, Yuseong-gu, Daejeon, Korea
- Product Category
- Other Examination & Testing Instrumnet
- Year Established
- 2014
- No. of Total Employees
- 1-50
- Company introduction
-
With company's philosophy of customer Satisfaction, Superiority and Specialization, TRISMED CO., LTD. was founded in 2000 and has been active in the research and development, manufacture and distribution on a world wide scale of cardiac diagnosis systems.
The wide-range products are targeted to offer reasonable price, international standard performance and high quality with our strong competence and deep experience.
TRISMED believes in coming true the leader in the cardiac diagnosis systems such as various Electrocardiographs(ECG), patient monitors and pulse oximeter in the world-wide.
Our quality system complies with the international quality standard - EN ISO13485:2003 and EC Council Directives 93/42/EEC CE(MDD).
- Main Markets
-
Austria
Romania
Spain
Turkey
U.S.A
- Main Product