MEGA CHECK TREATMENT

MEGA CHECK TREATMENT

Mega check (Treatment)


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
South Korea
Brand name
NABAKEM
Payment Terms
L/C,Others
Production method
Available,ODM,OEM
Shipping / Lead Time
Negotiable / Negotiable
Keyword
mega check (treatment)
Category
Other Chemicals

NABAKEM.CO.,Ltd

Membership
PRO
Country / Year Established
South Korea South Korea / 1980
Business type
Manufacturer
Verified Certificate

9

TRADE TOWER

DUNS

Product name MEGA CHECK TREATMENT Certification -
Category Other Chemicals Material -
Keyword mega check (treatment) Unit Size -
Brand name NABAKEM Unit Weigh -
origin South Korea Stock 10000
Supply type Available,ODM,OEM HS code 3814

Product Information

Features• Special equipment not required. Used anytime anywhere.

• Easy-to-use.

• This product changes invisible fine cracks into visible red-colored cracks, enabling you to check all cracks.

• It can be used regardless of material or form of inspection object.

• Easy-to-use and highly portable one touch aerosol type.

• Corrosive materials not used.

• Safe for aluminum alloy and magnesium alloy subject to easy corrosion.

• Inspection results are maintained as they are, unless you clean them.

• Aerosol product ensures clean use, making you maintain cleanliness of workplace.



Uses• It can be used for nonferrous materials like porcelain, glass, synthetic resin as well as metal, iron, nonferrous metal, magnetic substance and nonmagnetic substance.

• Casting parts ----- pin hole, scalding flaw, shrinkage flaw forging parts ----- forging flaw.

• Weld ----- crack, failed joining.

• Metal materials ----- grinding flaw, heat flaw, cutting tool crack.

• Leakage check ----- tank, boiler, pipe etc.



How to Use
• Coloring Penetration Detection Method disovers invisible flaws easily by making red penetrant liquid penetrate into surface flaw areas of inspection object, removing residual red penetrant liquid with cleaner, and developing red penetrant in flaw areas by using white developer and capillary phenomenon.

• Everyone can use the detection method by following operations.

1. Pre-treatment
The dirt like dust, oil content, coating materials and rust prevents.
penetration of red penetrant. Remove them completely with cleaner before inspection.
Be careful of pre-treatment method to prevent surface flaw areas from being clogged.
The more perfect the pre-treatment is, the higher the detection effects are and the easier the inspection operations.

2. Penetration
Clean the inspection object surface and dry it.
Apply red penetrant evenly 20~30cm away from target object to make the surface covered with the penetrant.
Penetration time is 2∼3 minutes. Application at the intervals of 3∼6 minutes ensures better effects.
Recommended temperature of parts for inspection is about 10∼40℃.
When you do this inspection work outdoors in winter, it is recommended that you should lengthen penetration by about two times to obtain better penetration effects.
(Also, as soluble penetrant is available, water rinsing is possible and onsite use is very easy.)

3. Cleaning
After penetration treatment is done, remove red penetrant remained on the inspection object by using dry dustcloth, tissue paper, other absorbents or water rinsing (in case of soluble penetrant) and clean the object with dustcloth containing cleaner or tissue papers.
If weld with surface not smoothed or inspection object with black film of steel and casting products are not cleaned completely, and red penetrant is remained on their surfaces, it is difficult to determine flaws correctly in developing.
Use white or near-white dustcloth or tissue paper to know cleaning degree easily.
Do not apply it directly to the surface of inspection object.

4. Development
After cleaning red penetrant remained after penetration, apply white developer evenly to make it cover whole surface.
Applied white developer is dried immediately, showing white color.
As it dries, red penetrant in flaw areas is absorbed and appeared, making the position and shape of flaw marked sharply on the white powder phase.
Shake white developer light before use.

5. Inspection
The areas not showing red after development means that they have no flaws.
Determine the kinds, size and depth of redstained areas on the basis of their shape and size.
The kinds of flaw created by color fixation can not be determined by a single word, but we can show them as following.

Cautions• Keep it away from your children.


• This flammable product uses high-pressure gas.

• Comply with following cautions.
 
1 .Do not use it toward fire.
 
2. Do not use near heater or stove.
 
3. Do not use in the room using fire.
 
4. Do not keep it in the place above 40℃.
 
5. Provide ventilation to use it in the closed room.
 
6. Do not throw it away into fire.
 
7. Punch the can to throw it away.
 
8. Do not keep it in the closed place.
 
9. Spraying may not work well below 5℃.



*Packaging Unit

Aerosol 450㎖/can, 20cans/Box

 

B2B Trade

Price (FOB) Negotiable transportation Air Transportation,Ocean Shipping
MOQ Negotiable Leadtime Negotiable
Payment Options L/C,Others Shipping time Negotiable

NABAKEM.CO.,Ltd

Country / Year Established
South Korea South Korea / 1980
Membership
PRO
Business type
Manufacturer

9

TRADE TOWER

DUNS

President
Kim Jonghyeok
Address
Paengseong-eup, Chupalsandan 1-gil,204, Pyeongtaek-si, Gyeonggi-do, Korea
Product Category
Other Machinery & Industry Equipment
Year Established
1980
Company introduction

NABAKEM never stops thinking of the betterment ofitself, produces the chemicalproducts and Aerosols that are needed for a wide range of industries which suchas shipbuilding,automobile, steel, fabric, etc. NABAKEM shows remarkable growth with the best chemicalmaking skills and innovative facilities.

 

Please visit our website for further information.

 

www.nabakem.com

 

 

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My TK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more